2010
DOI: 10.1016/j.biomaterials.2010.06.023
|View full text |Cite
|
Sign up to set email alerts
|

A series of naphthalimide derivatives as intra and extracellular pH sensors

Abstract: A series of new naphthalimide derivatives were synthesized and studied. Three of the materials (SM1, SM2, and SM3) possess methacrylate(s) moieties as pH sensor monomers, enabling these compounds to be polymerized with other monomers for thin film preparation for extracellular pH sensing. Herein, poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) (PHEMA-co-PAM) was chosen as the polymer matrix. Structure influences on pH responses and pKa values were studied. The film P3 composed of the sensing moiety SM3 h… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
73
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 108 publications
(75 citation statements)
references
References 53 publications
(66 reference statements)
2
73
0
Order By: Relevance
“…For the pH sensitive probe 5(6)-carboxyfluorescein N-hydroxysuccinimide ester was covalently linked to an amino-modified pHEMA copolymer (amino-pHEMA) based on earlier work on the polymerization of HEMA [46,[48][49][50] by the following procedure:…”
Section: Preparation Of Ph Probe and Reference Polymersmentioning
confidence: 99%
“…For the pH sensitive probe 5(6)-carboxyfluorescein N-hydroxysuccinimide ester was covalently linked to an amino-modified pHEMA copolymer (amino-pHEMA) based on earlier work on the polymerization of HEMA [46,[48][49][50] by the following procedure:…”
Section: Preparation Of Ph Probe and Reference Polymersmentioning
confidence: 99%
“…We are developing an ATP sensor system, and are in the process of optimizing custom optical sensors that can be embedded in polymer matrices pH, K þ , and temperature sensing. [36][37][38][39] In the near future we will combine a fully automated platform developed by our group for spectrally-resolved measurement of multiparameter sensor responses, combined with a microfluidics module for serial or parallel delivery of biochemical and environmental stimuli to cells confined in arrays of microwells. We will combine metabolic profile measurements with gene transcription level profiling at the single-cell level that will be applied after phenotype characterization to establish the relationships between expression levels of specific genes and cell phenotypes.…”
Section: Conclusion and Future Outlookmentioning
confidence: 99%
“…Several probes for Zn 2+ and Cu 2+ have been reported [13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31] with 4-amino-1,8-naphthalimide as the signalling moiety, but none of them are useful for detection of both the metal ions on duel "off-on" or "on-off " modes. Generally, the fluorescence of 4-piperazino-1,8-naphthalimide derivatives is quenched due to PET arising from the piperazine nitrogen [32][33][34][35]. In the present study, binding of a Zn 2+ ion quenches the PET process, resulting in the fluorescence emission from the chemosensor.…”
Section: Introductionmentioning
confidence: 78%
“…The fluorescence of 4-piperazino-1,8-naphthalimide derivatives are usually quenched either completely or partially due to PET [32][33][34][35]. During our screening experiments involving different solvents and metal ions, probe 1 showed significant quantum of fluorescence in aqueous and non-aqueous media indicating partial quenching due to PET process.…”
Section: Metal Ion Selectivity and Sensitivity Of Probementioning
confidence: 97%