2014
DOI: 10.1109/tpel.2013.2283368
|View full text |Cite
|
Sign up to set email alerts
|

A Series-Connected Topology of a Diode Rectifier and a Voltage-Source Converter for an HVDC Transmission System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
66
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 126 publications
(70 citation statements)
references
References 14 publications
0
66
0
Order By: Relevance
“…(18) and (19), if a small variation occurs in v L Lrms (t) (e.g., v L Lrms (t) = V L L + |v s (t)|) and in δ (e.g., δ + |δ(t)|), it will directly impact v d (t) and i d (t) such to become, respectively, V d + |v d (t)| and I d + |î d (t)|. Therefore, controlling the variations magnitudes |v d (t)| and |v d (t)| results in regulating v L L (t) and δ.…”
Section: Controller Design For Active Rectifiermentioning
confidence: 99%
See 2 more Smart Citations
“…(18) and (19), if a small variation occurs in v L Lrms (t) (e.g., v L Lrms (t) = V L L + |v s (t)|) and in δ (e.g., δ + |δ(t)|), it will directly impact v d (t) and i d (t) such to become, respectively, V d + |v d (t)| and I d + |î d (t)|. Therefore, controlling the variations magnitudes |v d (t)| and |v d (t)| results in regulating v L L (t) and δ.…”
Section: Controller Design For Active Rectifiermentioning
confidence: 99%
“…Based on Eqs. (18) and (26), the output RMS voltage to the PMSG is V L Lrms = 2 kV , the output voltage of a single diodebridge rectifier is V d = 2.7 kV , the output voltage of the active rectifier is V d0 = 3 kV , and the duty ratio D = 0.1. The DC current is obtained using Eq.…”
Section: Offshore Wind Park: Sample System Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…the offshore wind farm site and connected to a conventional MMC at onshore has received noticeable interests [8]- [15]. This approach was firstly suggested in [8]- [11], and has been further developed in industry for offshore wind farm connection [12], [13].…”
Section: Introductionmentioning
confidence: 99%
“…However, system performances under DC fault condition and fault recovery control method are not fully analyzed. A novel converter topology consisting of a series connection of 12-pluse diode rectifiers and VSC is proposed [24] for integrating an offshore wind farm with reduced cost and power loss. The dynamic performances under changing load and AC grid fault are investigated.…”
Section: Introductionmentioning
confidence: 99%