2013
DOI: 10.1109/tec.2013.2278379
|View full text |Cite
|
Sign up to set email alerts
|

A Series-Connected Photovoltaic Distributed Generator Capable of Enhancing Power Quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(19 citation statements)
references
References 20 publications
0
19
0
Order By: Relevance
“…In order to confirm the above mentioned work, a modest single phase system is established and verified for different voltage sag/swell disorders. To authenticate the performance of Type-2 FLC, it is analysed with two cases and compared with traditional controller techniques [17,18]. From the paper [17,18], power quality features are improved with the help of PI controller and ANFIS (Adaptive Neuro Fuzzy Inference System) controller.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to confirm the above mentioned work, a modest single phase system is established and verified for different voltage sag/swell disorders. To authenticate the performance of Type-2 FLC, it is analysed with two cases and compared with traditional controller techniques [17,18]. From the paper [17,18], power quality features are improved with the help of PI controller and ANFIS (Adaptive Neuro Fuzzy Inference System) controller.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
“…To authenticate the performance of Type-2 FLC, it is analysed with two cases and compared with traditional controller techniques [17,18]. From the paper [17,18], power quality features are improved with the help of PI controller and ANFIS (Adaptive Neuro Fuzzy Inference System) controller. The results from those papers are compared with the proposed technique in the below mentioned comparison table 1.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
“…Since the location of PV arrays may have an impact on the optimization results, two configurations are thus studied for comparison. In the first configuration, the PV arrays are connected to the buses {2, 5,6,9,10,13,33,35,40,55,66,78,91,92,106,121,119,118,104, 107} and in the other configuration, the PV arrays are connected to the buses {5, 16, 29, 33, 46, 43, 41, 59, 96, 92, 90, 88, 64, 83, 79, 75, 71, 118, 104, 107}. Fig.…”
Section: B 123-bus Test Systemmentioning
confidence: 99%
“…In [6] and [7], combining energy storage and PV generation to facilitate scalable plants was studied. It was [8] and [9] that investigated the power quality issues of PV power plants, such as voltage dips and supply interruptions. While [10]- [13] focused on the study of the current harmonic distortion from PV-inverter integration.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the modernization of the 11 kV and 400 V distribution network is critical to integrate non-conventional renewable energies, DG and EVs without losing reliability, power quality and efficiency. Possible solutions are to engage the management of DG and EVs connections [2], add mesh connection to radial feeders [3], use active compensation or energy storage systems [4], and implement soft-open-points (SOPs) to obtain a soft meshed distribution network with power-flow-control [5], [6].…”
Section: Introductionmentioning
confidence: 99%