2019
DOI: 10.1016/j.jelechem.2018.12.035
|View full text |Cite
|
Sign up to set email alerts
|

A sequential process to treat a cashew-nut effluent: Electrocoagulation plus electrochemical oxidation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 49 publications
0
5
0
Order By: Relevance
“…Before starting the electrolysis, the Nb/BDD (Metakem, Germany) electrode was polarized during 30 min with 130 mL of 0.1 M H 2 SO 4 solution at 30 mA cm À 2 , in order to remove any kind of impurity from the material. [35] Anode and cathode were connected a Politerm POL-16 power supply and the experiments were performed under galvanostatic conditions. pH was measured by a HANNA HI4221 pH-meter and adjusted prior to the tests using 1 M H 2 SO 4 (CRQ Química) or 3 M NaOH (Cromoline).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Before starting the electrolysis, the Nb/BDD (Metakem, Germany) electrode was polarized during 30 min with 130 mL of 0.1 M H 2 SO 4 solution at 30 mA cm À 2 , in order to remove any kind of impurity from the material. [35] Anode and cathode were connected a Politerm POL-16 power supply and the experiments were performed under galvanostatic conditions. pH was measured by a HANNA HI4221 pH-meter and adjusted prior to the tests using 1 M H 2 SO 4 (CRQ Química) or 3 M NaOH (Cromoline).…”
Section: Methodsmentioning
confidence: 99%
“…Their working area was 3.0 cm 2 and the interelectrode gap distance was kept about 1 cm. Before starting the electrolysis, the Nb/BDD (Metakem, Germany) electrode was polarized during 30 min with 130 mL of 0.1 M H 2 SO 4 solution at 30 mA cm −2 , in order to remove any kind of impurity from the material . Anode and cathode were connected a Politerm POL‐16 power supply and the experiments were performed under galvanostatic conditions.…”
Section: Methodsmentioning
confidence: 99%
“…It could be an integration of the electrochemical method with physical, chemical, biological methods. The advantages of this integration are the effective removal of organic and inorganic pollutants [146], low operating costs [142], the increase of the performance of the electrodes and the reduction of the energy demand of the electrochemical method [147].…”
Section: Integration Of Electrochemical Treatment With Other Methodsmentioning
confidence: 99%
“…According to a previous study, even though the COD removal for PPW is categorized as low, the phenolic compound removal shows greater efficiencies. In addition, using graphite as the electrode material on PPW could achieve the complete removal of phenolic compounds and the 99.79% removal of COD [142].…”
Section: Nuts Processing Wastewatermentioning
confidence: 99%
“…Our meticulous analysis of the literature established that hybrid approaches based on electrochemical and AOPs were effective at removing contaminants from synthetic wastewater (Zazou et al 2019;Chanikya et al 2021). Meanwhile, only a few studies have focused on real wastewater and industrial effluent utilizing hybrid electrochemical and AOPs (Valero et al 2017;da Costa et al 2019). Additionally, apart from the removal of contaminants from industrial effluent and wastewater, the hybrid process's EEC is critical from an economic standpoint.…”
Section: Introductionmentioning
confidence: 99%