2010
DOI: 10.1243/09544062jmes1933
|View full text |Cite
|
Sign up to set email alerts
|

A sensory-guided surgical micro-drill

Abstract: Abstract:In this paper a surgical robotic device is described that is able to discriminate tissue interfaces and other controlling parameters ahead of the drill tip. The advantage in surgery is that tissues at interfaces can be preserved. The smart tool detects ahead of the tool point and is able to control interaction with respect to the flexing tissue to avoid penetration or to control the extent of protrusion with respect to the position of the tissue. For surgical procedures where precision is required the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(23 citation statements)
references
References 11 publications
0
23
0
Order By: Relevance
“…Perforation of the endosteal membrane by the drill may result in contamination of the endolymph and perilymph with bone dust, increase the risk of postoperative infection and reduce the residual hearing. To accommodate this problem, Brett et al have developed an autonomous micro‐drilling robot performing the cochleostomy (45,46). The robot consists of the micro‐drill mounted on a linear guide, attached to a passive robotic arm (Figure 8).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Perforation of the endosteal membrane by the drill may result in contamination of the endolymph and perilymph with bone dust, increase the risk of postoperative infection and reduce the residual hearing. To accommodate this problem, Brett et al have developed an autonomous micro‐drilling robot performing the cochleostomy (45,46). The robot consists of the micro‐drill mounted on a linear guide, attached to a passive robotic arm (Figure 8).…”
Section: Resultsmentioning
confidence: 99%
“… The micro‐drilling surgical robotic system used by Taylor et al (46) for robotic cochleostomy. Reproduced by permission of SAGE Publications Ltd…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Feedback is by observation of behaviour under the binocular microscope [12, 13]. Standard surgical drilling burrs are used.…”
Section: Drilling Processmentioning
confidence: 99%
“…Recently, Taylor et al [15] presented a surgical robotic device that is able to discriminate tissue interfaces and other controlling parameters in the space in front of the drill tip. A smart tool detects the area just in front of the tool tip and is able to control the interaction with respect to the flexing tissue in order to avoid penetration or to control the extent of protrusion with respect to the position of the tissue.…”
Section: Related Workmentioning
confidence: 99%