2014
DOI: 10.1016/j.tsf.2013.12.037
|View full text |Cite
|
Sign up to set email alerts
|

A sensitive bithiophene-based biosensor for interferon-gamma characterization and analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…The thiophene-based gold chips were rinsed thoroughly with THF, ethanol and distilled water and then dried with nitrogen before being assembled onto the holder. An ellipsometry instrument built by our team was used to measure the physical characteristics of the bithiophene biolinker on a home-made self-coated Au chip [ 24 ]. A total of 10 measurement points were taken to obtain the mean values and standard deviation of the bithiophene biolinker, i.e., refraction index (RI) was 1.5355 ± 0.2567 and thickness was 3.0111 ± 0.6964 nm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The thiophene-based gold chips were rinsed thoroughly with THF, ethanol and distilled water and then dried with nitrogen before being assembled onto the holder. An ellipsometry instrument built by our team was used to measure the physical characteristics of the bithiophene biolinker on a home-made self-coated Au chip [ 24 ]. A total of 10 measurement points were taken to obtain the mean values and standard deviation of the bithiophene biolinker, i.e., refraction index (RI) was 1.5355 ± 0.2567 and thickness was 3.0111 ± 0.6964 nm.…”
Section: Methodsmentioning
confidence: 99%
“…For rapid screening simulation of an antisera antibody experiment, we synthesized a 1.23 nm bithiophene-based conductive biolinker [ 24 ] to enhance and verify the anti-IFN-γ antibody interaction detection capability of our system. In our study, the bithiophene linker was employed to examine the thin film surface coating and its specific binding ability of a sensor surface.…”
Section: Introductionmentioning
confidence: 99%
“…The semi-conductive linker CS20S (5'-(mercapto)-[2, 2'-bithiophene]-5-carboxylic acid) was dissolved in tetrahydrofuran (THF) that was synthesized within the team [12]. The anti-human IFN-γ Ab, recombinant human IFN-γ, and monoclonal mouse IgG were obtained from R&D Systems (Minneapolis, MN, USA).…”
Section: Materials and Self-assembled Monolayermentioning
confidence: 99%
“…As far as examples of application in medicine and pharmaceutical science are concerned, 5-(4-hydroxyphenyl)-5'-dicyanoethenyl-2,2'-bithiophene was tested as a marker of cell lesions in Alzheimer’s disease [8]. Moreover, 5'-mercapto-2,2'-bithiophene-5-carboxylic acid was tested as a potential biosensor detecting antigen-antibody connection [9], and a series of 5-( E )-styryl-2,2'-bithiophenes were tested as potential β-amyloid probes [10]. The starting substances for the synthesis of these compounds are simple derivatives of thiophene, bithiophene or oligothiophene substituted by Li, Br, I, C≡CH, MgCl, SnBu 3 , B(OH) 2 , B(OR) 2 , or ZnCl, which facilitate the chemical modification of their structures.…”
Section: Introductionmentioning
confidence: 99%