A Sensitive Analytical Procedure for the Determination of Primary and Secondary Alkanolamines in Air

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

1997
1997
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…These methods have been used with various detection modes such as electrospray ionization mass spectrometry (ESIMS), 16 chemiluminescence, 17 pulsed amperometry, 2,18,19 suppressed conductivity, 20,21 refractometry 22 and UV detector (after derivatization with 9-fluorenylmethyl chloroformate). 23–25 Headley et al even revised the analytical methods for the determination of alkanolamines such as diethanolamine (DEA) and methyl-diethanolamine (MDEA). 26 Plasmonic sensors based on the theoretical concept of metal–insulator–metal (MIM) geometry and micro-ring-based sensors have also been reported.…”
Section: Introductionmentioning
confidence: 99%
“…These methods have been used with various detection modes such as electrospray ionization mass spectrometry (ESIMS), 16 chemiluminescence, 17 pulsed amperometry, 2,18,19 suppressed conductivity, 20,21 refractometry 22 and UV detector (after derivatization with 9-fluorenylmethyl chloroformate). 23–25 Headley et al even revised the analytical methods for the determination of alkanolamines such as diethanolamine (DEA) and methyl-diethanolamine (MDEA). 26 Plasmonic sensors based on the theoretical concept of metal–insulator–metal (MIM) geometry and micro-ring-based sensors have also been reported.…”
Section: Introductionmentioning
confidence: 99%
“…In their method, the excess FMOC was removed by extraction with pentane 7) . However, that procedure was not sufficient to remove excess FMOC and may cause loss of the analytes.…”
Section: Modification Of the Published Sample Preparation Procedures Amentioning
confidence: 99%
“…The relative standard deviations, which represent the overall reproducibility defined as precision, were 0.3-1.6 and 0. Osaka Office, Sigma-Aldrich Japan K.K., Japan, liquid chromatography (HPLC) with fluorescence detection 7) . The purpose of this study was the development of a robust method for simultaneous determination of MEA and DEA in workplace air with the sampling capacity and sensitivity required for the MHLW exposure survey.…”
mentioning
confidence: 99%
See 1 more Smart Citation