2009
DOI: 10.1590/s0103-50532009000200010
|View full text |Cite
|
Sign up to set email alerts
|

A semi-continuous analyzer for the fluorimetric determination of atmospheric formaldehyde

Abstract: Este trabalho descreve o analisador semi-contínuo (FORMAL-FLU) sensível e seletivo para determinação fluorimétrica de formaldeído no ar atmosférico. O método é baseado na reação entre formaldeído e Fluoral-P, produzindo o derivado fluorescente 3,5-diacetil-1,4-diidrolutidina (DDL), que quando excitado em 410 nm, emite fluorescência em 510 nm. O analisador consiste de uma câmara difusora de gases com um tubo de teflon microporoso, com alta permeabilidade, preenchido com solução de Fluoral-P. A amostra de ar é b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 27 publications
(52 reference statements)
0
3
0
Order By: Relevance
“…Fluoral-P is colorless, while the product of reaction with FA, 3,5-diacetyl-1,4-dihydrolutidine (DDL), is yellow and can be detected by a spectrophotometer at 420 nm ( Figure 7 B). As many others, this protocol was initially applied to FA monitoring in air samples [ 109 , 110 ]. Subsequently, this approach was used by Yue and colleagues to estimate FA content in brain tissue lysates [ 111 ].…”
Section: From In Vitro To In Cellulomentioning
confidence: 99%
“…Fluoral-P is colorless, while the product of reaction with FA, 3,5-diacetyl-1,4-dihydrolutidine (DDL), is yellow and can be detected by a spectrophotometer at 420 nm ( Figure 7 B). As many others, this protocol was initially applied to FA monitoring in air samples [ 109 , 110 ]. Subsequently, this approach was used by Yue and colleagues to estimate FA content in brain tissue lysates [ 111 ].…”
Section: From In Vitro To In Cellulomentioning
confidence: 99%
“…299,300 A semi-continuous analyzer based on two concentric tubes was proposed for fluorimetric determination of atmospheric formaldehyde. 301 The air sample was continually pumped through the external tube and the analyte was collected in a central microporous PTFE tube filled with the Fluoral-P reagent. Under optimized conditions defined by the Box-Behnken design, the detection limit and coefficient of variation were estimated as 0.55 ng L -1 and 8.6%, respectively.…”
Section: Instrumentation and Automationmentioning
confidence: 99%
“…17 Procedures based on fluorimetric or spectrophotometric detection using acetylacetone (2,4-pentadione) for chemical derivatization have been commonly used. 18 The acetylacetone method was developed by Nash 19 and based on Hantzsch reaction. Formaldehyde reacts with acetylacetone in presence of ammonium acetate leading to the formation of 3,5-diacetyl-1,4-dihydrolutidine (DDL).…”
Section: Introductionmentioning
confidence: 99%