2019
DOI: 10.4244/eij-d-18-00715
|View full text |Cite
|
Sign up to set email alerts
|

A self-expanding percutaneous valve for patients with pulmonary regurgitation and an enlarged native right ventricular outflow tract: one-year results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
35
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(37 citation statements)
references
References 17 publications
1
35
1
Order By: Relevance
“…The differences between the RVOT dimensions on CMR and balloon interrogation made the latter a mandatory step. [ 11 12 13 14 15 16 17 ] After placing a stiff Lunderquist guidewire (Cook medical, Bloomington, IN) to straighten the outflow tract, marker pigtail angiograms were performed in orthogonal projections to measure the RVOT dimensions. Once the hemodynamics was recorded, a long compliant AGA sizing balloon (Abbott, Plymouth, MN) was inflated across the outflow until a right ventriculogram confirmed complete occlusion.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The differences between the RVOT dimensions on CMR and balloon interrogation made the latter a mandatory step. [ 11 12 13 14 15 16 17 ] After placing a stiff Lunderquist guidewire (Cook medical, Bloomington, IN) to straighten the outflow tract, marker pigtail angiograms were performed in orthogonal projections to measure the RVOT dimensions. Once the hemodynamics was recorded, a long compliant AGA sizing balloon (Abbott, Plymouth, MN) was inflated across the outflow until a right ventriculogram confirmed complete occlusion.…”
Section: Methodsmentioning
confidence: 99%
“…In the third design, this thin pericardial lining was removed from the six open cells in the distal flare. [ 11 12 13 14 ] The fourth design since 2018 had five open cells in distal flare that connected all the sharp edges to the outer wire frame [ Figure 1 ]. The valve was rinsed to remove the glutaraldehyde preservative and crimped in ice-cold saline to reduce the nitinol memory, using a proprietary compression device and loaded on the delivery system.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Table 3 summarizes clinical studies of the commercially approved valves and the new self-expanding valves reported in the literature. Early experience with these valves, although limited, has been encouraging, suggesting that self-expandable pulmonary valves can be implanted safely in patients with native RVOTs, with good short-and mid-term results [55][56][57][58][59][60][61][62].…”
Section: Future Perspectivesmentioning
confidence: 99%
“…Although the implant numbers are very small, we have not seen endocarditis on this valve yet. This holds true for the multiple published cohorts of the flared Venus P-valve™ with one exception from a multi-center Chinese experience 32. In this cohort (n = 55) studied by Zhou et al one patient died of endocarditis within 1 year of implantation of a flared Venus P-valve™.5 | LIMITATIONSThis study suffers from the usual disadvantages of a multicentre, retrospective cohort.…”
mentioning