1975
DOI: 10.1002/xrs.1300040204
|View full text |Cite
|
Sign up to set email alerts
|

A self‐consistent calibration method for industrial X‐ray spectrometric analyses

Abstract: A fast, efficient calibration procedure is proposed based on the accurate analysis of multicomponent systems by means of the influence coefficient method. It relies on a series of well designed additions made to a suitable standard composition, the latter also being used as a reference sample. We show that, for an n element composition, using the hypothesis of constant coefficients, (n + 1) preparations – allowing n(n + 1) intensity measurements – are in principle sufficient to calculate the n2 calibration par… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

1975
1975
1991
1991

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…The mathematical and physical meanings, and effects of every variable in the equations are probed. In accordance with these investigations, it is possible to generalize earlier specific calculation problems (1)(2)(3)(4)(5)(6)(7)(8) encountered in XRF methods.…”
mentioning
confidence: 59%
“…The mathematical and physical meanings, and effects of every variable in the equations are probed. In accordance with these investigations, it is possible to generalize earlier specific calculation problems (1)(2)(3)(4)(5)(6)(7)(8) encountered in XRF methods.…”
mentioning
confidence: 59%
“…third-element effects, will in general cause small deviations from the true values and have to be accounted for if an accurate analysis is to be obtained. 22 The calculated third-element correction factors for the samples are low (0.001-0.03), but not insignificant, although in general they are assumed to be almost negligible.7,21-24 This may be due to the fairly high concentration of the added internal standard, in relation to the concentrations of the analyte elements, as the concentration of the internal standard is carried forward in the calculation of the third-element correction factor.…”
Section: ~~mentioning
confidence: 99%
“…( 1 ) The expression inside the brackets in Eqn ( trend is parallel to the actual concentration axis, Ci. ( 5 ) If the calculated emitter concentration is too high only for samples with a high absorber concentration q, then the factor qi is too large.…”
Section: Appendix Guidelines For Amending Matrix Parametersmentioning
confidence: 99%