2016
DOI: 10.1016/j.saa.2016.02.040
|View full text |Cite
|
Sign up to set email alerts
|

A selective fluorescent ‘turn-on’ sensor for recognition of Zn2+ in aqueous media

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
3

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 47 publications
0
6
0
3
Order By: Relevance
“…Therefore, research interest in the recognition of Zn 2+ and PPi has increased. Considerable efforts have been made to recognize Zn 2+ ions, such as spectrometry, electrochemistry, and chromatography . For the selective and sensitive detection PPi, fluorescence assays, colorimetric assays, and electro‐optical methods have also been developed.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, research interest in the recognition of Zn 2+ and PPi has increased. Considerable efforts have been made to recognize Zn 2+ ions, such as spectrometry, electrochemistry, and chromatography . For the selective and sensitive detection PPi, fluorescence assays, colorimetric assays, and electro‐optical methods have also been developed.…”
Section: Introductionmentioning
confidence: 99%
“…This is actually a classic behavior of fluorescent molecules derived from rhodamine-based scaffolds. [39,43,46] Furthermore, when incubating each competitive metal ion-including Na + , K + , Ca 2 + , Mg 2 + , Ag + , Cr 3 + , Fe 3 emission were observed, as indicated in Figure 3. In short, the fluorescence behavior of these two sensors toward the selected metal ions was almost identical.…”
Section: The Fluorescence Performance Of the Rp1 And Rp2 Probesmentioning
confidence: 84%
“…Following interaction of the probes with target speciessuch as cations, anions and neutral molecules -or by exposure to external factors such as heat and pressure, broadband amplification could be observed in both the UV-Vis absorption and fluorescence emission spectra. [6,[37][38][39][40][41][42][43][44][45][46][47][48][49] The instrumental analyses are verified in detail, which are included in the supplementary electronic information.…”
Section: Synthesis Of Chemosensorsmentioning
confidence: 99%
“…Kemosensör C1 ile Fe 2+ metal iyonu arasındaki bağlanma modunu araştırmak için Job's plot deneyi yapılmıştır (Ozdemir, 2016 Şekil 8: Job's plot metoduyla kemosensör C1 ile Fe 2+ iyonları arasındaki muhtemel bağlanma oranları.…”
Section: Job's Plot Uygulaması Bağlanma Sabiti Ve Tayin Alt Sınırınıunclassified
“…Diğer taraftan, floresan titrasyon spektrumlarındaki emisyon yoğunlukları (1/F-F0, λem= 529 nm) demir iyonu konsantrasyonlarına (1/[Fe 2+ ] karşı Benesi-Hildebrand eşitliği (1) kullanılarak Şekil 9 (1)'deki grafik elde edilmiştir (Ozdemir, 2016). Buradaki verilerden bağlanma sabiti (Ka) aşağıdaki eşitlik kullanılarak hesaplanmış olup 1.95x10 4 M -1 olarak bulunmuştur.…”
Section: Job's Plot Uygulaması Bağlanma Sabiti Ve Tayin Alt Sınırınıunclassified