2011
DOI: 10.1016/j.enbuild.2010.11.002
|View full text |Cite
|
Sign up to set email alerts
|

A screening methodology for implementing cost effective energy retrofit measures in Canadian office buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
46
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 149 publications
(50 citation statements)
references
References 6 publications
0
46
0
2
Order By: Relevance
“…As compared to other previous studies [2,10,[24][25][26][27][28][29][30][31] the research carried out has studied the issue of projects for increasing the energy efficiency of the dwelling stock at regional and county level, showing that an optimal portfolio of projects at the regional level can be created by using LCC as a criterion for setting up this portfolio. LCC ro was determined in the research, corresponding to the optimal portfolio of projects at a regional level.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…As compared to other previous studies [2,10,[24][25][26][27][28][29][30][31] the research carried out has studied the issue of projects for increasing the energy efficiency of the dwelling stock at regional and county level, showing that an optimal portfolio of projects at the regional level can be created by using LCC as a criterion for setting up this portfolio. LCC ro was determined in the research, corresponding to the optimal portfolio of projects at a regional level.…”
Section: Discussionmentioning
confidence: 99%
“…The ratio between the glazed surface and the total building envelope is: South-4.89%; East-2.40%; North-4.89%; West-2.40%. The use of the building is equivalent to the building block proposed in Appendix A (Table A1) [20][21][22][23][24] • C in winter and 22-27 • C in the summer. Moisture humidity is 60% both in summer and winter.…”
Section: Research Methodology Materials and Methodsmentioning
confidence: 99%
“…The paper investigates heat metering in the non-disconnected and the disconnected residence from DHS in a multistory residential building by using EnergyPlus software and relevant computer simulations. The software was already used for the research in multistory buildings (Chidiac et al 2011) for such investigations in similar moderate climates like in Serbia. The residence has a low heat demand compared to the average heat demand of all DHS consumers.…”
Section: Introductionmentioning
confidence: 99%
“…The optimal design created by an automatic process facilitates the designer's Energies 2017, 10, 59 4 of 21 decision making that considers the reality of nZEB [18]. It also acts to relieve the designer of a very time-consuming and labor-intensive trial and error approach, which designs and evaluates a number of buildings to reach the same goal [19].…”
Section: Decision Making For Realization Of Zero Emission Buildingmentioning
confidence: 99%