2011
DOI: 10.1016/j.bios.2010.11.018
|View full text |Cite
|
Sign up to set email alerts
|

A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0
1

Year Published

2011
2011
2017
2017

Publication Types

Select...
4
4
2

Relationship

0
10

Authors

Journals

citations
Cited by 105 publications
(36 citation statements)
references
References 18 publications
(15 reference statements)
0
35
0
1
Order By: Relevance
“…Per example, in the paper by Crew et al [69], the cross response of six genetically modified AChEs (B03, B04, B65, B131, B394 and B421) was evaluated against six organophosphate pesticides. Figure 24 shows pictorially the different patterns of inhibition presented by each AChE enzyme evaluated, clearly displaying the different patterns by each pesticide and announcing that the resolution of pesticide mixtures is possible.…”
Section: Determination Of Pesticidesmentioning
confidence: 99%
“…Per example, in the paper by Crew et al [69], the cross response of six genetically modified AChEs (B03, B04, B65, B131, B394 and B421) was evaluated against six organophosphate pesticides. Figure 24 shows pictorially the different patterns of inhibition presented by each AChE enzyme evaluated, clearly displaying the different patterns by each pesticide and announcing that the resolution of pesticide mixtures is possible.…”
Section: Determination Of Pesticidesmentioning
confidence: 99%
“…Como consequência, têm mostrado alta versatilidade de aplicações, tanto na forma de eletrodo convencional, quanto na forma de eletrodo modificado. [21][22][23][24][25][26][27][28][29][30][31][32][33] Ademais, dependendo da aplicação, esses eletrodos podem ser empregados muitas vezes, barateando ainda mais o custo das determinações analíticas.…”
Section: Os Eletrodos De Mercúrio (Dme -Dropping Mercury Electrode Hunclassified
“…A rapid, reliable, economical and portable analytical system will be of great benefit in the detection and prevention of OPs contamination. A biosensor array based on six acetylcholinesterase enzymes coupled with a novel automated instrument incorporating a neural network program has been reported by Hart et al [44] . The biosensor array and the instrument is illustrated in Figure 12.…”
Section: Enzyme Based Biosensor Arraymentioning
confidence: 99%