A Rotating Disk Electrode Apparatus for the Study of Fuel Cell Reactions at Elevated Temperatures and Pressures

Abstract: not Available.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
13
0

Year Published

1985
1985
2016
2016

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 0 publications
2
13
0
Order By: Relevance
“…Various Tafel slopes have been reported for phosphoric acid fuel cells in the range of 90 and 135 mV dec −1 (α = 0.93− 0.62) at 150 • C [26][27][28][29][30][31][32]. An average value of alpha equal to 0.75 (112 mV dec −1 ) was considered in this work.…”
Section: Phosphoric Acid Concentration Temperature and Watermentioning
confidence: 99%
See 1 more Smart Citation
“…Various Tafel slopes have been reported for phosphoric acid fuel cells in the range of 90 and 135 mV dec −1 (α = 0.93− 0.62) at 150 • C [26][27][28][29][30][31][32]. An average value of alpha equal to 0.75 (112 mV dec −1 ) was considered in this work.…”
Section: Phosphoric Acid Concentration Temperature and Watermentioning
confidence: 99%
“…As shown elsewhere [23], values of transfer coefficient changed with doping level. For example, at 150 • C, the lowest Tafel slope observed at the minimum doping level of 4.5 PRU (4.5 mole per repeat PBI unit) was 92 mV dec −1 (α = 0.91) which increased to 104 mV dec −1 (α = 0.81) at a doping level of 10 PRU [24,25] and to 90-135 mV dec −1 (α = 0.93-0.62) for phosphoric acid fuel cells [26][27][28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…Methods involving macroelectrodes such as RDE [30] or RRDE [20] have the potential for fast determination of c and D, but they are impeded by the low solubility of O2 in concentrated PA. In this regard, working in pressurized systems is advantageous [31][32][33][34]. As a step towards studying the ORR at realistic conditions in pressurized half-cell setups, in the present study we therefore investigate the oxygen solubility and diffusivity in diluted phosphoric acid electrolyte in a temperature range of 5 to 80 °C.…”
Section: Introductionmentioning
confidence: 99%
“…Rotating disk voltammetric measurements were made using a 3 mm diameter glassy carbon working electrode driven by an AFMSRX Analytical Rotator System. McBreen et al (1984) described a rotating disk electrode apparatus for www.ccsenet.org/mas Modern Applied Science Vol. 10, No.…”
Section: Rotating Disk Electrode Apparatusmentioning
confidence: 99%