2010
DOI: 10.1186/1475-925x-9-24
|View full text |Cite
|
Sign up to set email alerts
|

A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

Abstract: BackgroundMaterial wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.MethodsA rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the roll… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 17 publications
0
12
0
Order By: Relevance
“…The predominant movement of the artificial knee in the sagital plane is a combination of a rollback of the femoral condyles upon the tibial plateau and a slidingmotion between these articulation partners [10]. As a consequence of these kinematics, the ISO 14243 standard describes adequate motion patterns [11].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…The predominant movement of the artificial knee in the sagital plane is a combination of a rollback of the femoral condyles upon the tibial plateau and a slidingmotion between these articulation partners [10]. As a consequence of these kinematics, the ISO 14243 standard describes adequate motion patterns [11].…”
Section: Introductionmentioning
confidence: 99%
“…Numerous test procedures have been designed and published addressing TKA materials, e.g., pin-on-disk (ASTM-standards), or knee simulators, mostly according to ISO 14243 [10,11,14].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…These tests are time and money consuming in cause of the prototype fabrication of the new knee endoprosthesis. In 2010, Richter et al [1] described a new wear test for specimens of simplified geometry under simulated rolling-slidingmovements according to knee endoprostheses. However, the physiological loading of the knee joint was not considered during static load application.…”
Section: Introductionmentioning
confidence: 99%