2018
DOI: 10.1016/j.bios.2018.04.036
|View full text |Cite
|
Sign up to set email alerts
|

A robust electrochemical immunosensor based on hydroxyl pillar[5]arene@AuNPs@g-C3N4 hybrid nanomaterial for ultrasensitive detection of prostate specific antigen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
29
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 90 publications
(30 citation statements)
references
References 90 publications
1
29
0
Order By: Relevance
“…Gold is another widely used material for electrode modification and antibody immobilization because of its biocompatibility [32]. Zhou et al developed an electrochemical immunosensor based on antibody-immobilized AuNPs [33]. The transducer used in that study was composed of antibodies immobilized on the AuNP layer for the detection of PSA.…”
Section: Physical Adsorption Of Antibodiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Gold is another widely used material for electrode modification and antibody immobilization because of its biocompatibility [32]. Zhou et al developed an electrochemical immunosensor based on antibody-immobilized AuNPs [33]. The transducer used in that study was composed of antibodies immobilized on the AuNP layer for the detection of PSA.…”
Section: Physical Adsorption Of Antibodiesmentioning
confidence: 99%
“…Copyright (2020) John Wiley and Sons., Inc. (B) Immunosensor with non-covalently immobilized antibodies on AuNPs. Reproduced with permission from [33]. Copyright (2018) Elsevier.…”
Section: Physical Adsorption Of Antibodiesmentioning
confidence: 99%
“…Also, on this fabricated immunosensor, gold nanoparticles (AuNPs) were adopted as effective nanomaterial for oriented immobilization of bioreceptors. AuNPs on the modified electrode can not only increase the amount of immobilized antibodies, but also speed up the electron transfer rate for signal amplification and thus increases the sensitivity of the designed immunosensor 37 , 38 . Therefore, the combination of NiFe-LDH/rGO nanocomposite and AuNPs should be a good immunosensing platform.…”
Section: Resultsmentioning
confidence: 99%
“…A solution containing the PSA was added to the electrode surface, followed by the nanobioconjugates. At optimal conditions, the immunosensor was tested by DPV with different PSA target concentrations, having a linear response in the range from 0.0005 to 10.00 ng/mL, with a LOD of 0.12 pg/mL, see Figure 2 III [ 30 ].…”
Section: Nanobioconjugates Assemblymentioning
confidence: 99%