A rhodamine based chemodosimeter for the detection of Group 13 metal ions

Abstract: A new rhodamine derivative, HL-CIN, derived from a reaction between N-(rhodamine-6G)lactam-ethylenediamine (L1) and trans-cinnamaldehyde, is reported here for the colorimetric and fluorogenic sensing of Group 13 trivalent cations, namely Al3+,...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 58 publications
0
5
0
Order By: Relevance
“…Few aspects of recently published rhodamine based chemosensors [9,10b,12a,d,17,27–40] for different metal ions have been compared with HL‐qui (Table S6). In most of the cases, excitation wavelength is about 500 nm whereas the emission is observed at 550 or ~580 nm.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Few aspects of recently published rhodamine based chemosensors [9,10b,12a,d,17,27–40] for different metal ions have been compared with HL‐qui (Table S6). In most of the cases, excitation wavelength is about 500 nm whereas the emission is observed at 550 or ~580 nm.…”
Section: Resultsmentioning
confidence: 99%
“…Recently, we have reported rhodamine derivatives for the sensing of trivalent metal ions of Group 13. [16,17] However, these probes could not identify Cr 3 + and Fe 3 + . There are other trivalent cations that need more attention.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…There are several chemosensors for Al 3+ in the literature. 11,13,[44][45][46][47][48][49][50][51][52][53][54][55] Some parameters of recently published chemosensors for Al 3+ are summarized in Table 1. Most of them have been synthesized by Schiff-base condensation reactions (exception: entry 5).…”
Section: Comparative Discussionmentioning
confidence: 99%
“…Our group very recently reported a chemodosimeter ( 110 ) (Scheme 20) which was constructed from a reaction between N -(rhodamine-6G)lactam-ethylenediamine and trans -cinnamaldehyde. 127 It underwent hydrolysis in the presence of Group 13 cations, namely, Al 3+ , Ga 3+ , In 3+ and Tl 3+ in HEPES buffer in H 2 O/ethanol = 1 : 9 (v/v; pH = 7.4) to give a pink color and strong fluorescence at 558 nm. Hydrolyzed products were a spirocyclic ring opened species, which was responsible for the color change and strong fluorescence, and cinnamaldehyde.…”
Section: Introductionmentioning