2009
DOI: 10.1016/j.aca.2009.06.030
|View full text |Cite
|
Sign up to set email alerts
|

A review on sequential injection methods for water analysis

Abstract: The development of fast, automatic and less expensive methods of analysis has always been the main aim of flow methodologies. The search for new procedures that still maintain the reliability and accuracy of the reference procedures is an ever growing challenge. New requirements are continually added to analytical methodologies, such as lower consumption of samples and reagents, miniaturisation and portability of the equipment, computer interfaces for full decision systems and so on. Therefore, the development… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
39
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 88 publications
(39 citation statements)
references
References 154 publications
0
39
0
Order By: Relevance
“…Micro Sequential Injection Lab-On-Valve (µSI-LOV) manifolds alleviate the majority of the drawbacks of FIA methods [12][13][14][15]. This technique is thus an attractive approach for shipboard analysis of trace metals since LOV manifolds are compact, fully automated, and provide highly precise fluidic manipulations in a miniaturized flow manifold with minimal reagent consumption and waste production.…”
Section: Graphical Abstractmentioning
confidence: 99%
See 1 more Smart Citation
“…Micro Sequential Injection Lab-On-Valve (µSI-LOV) manifolds alleviate the majority of the drawbacks of FIA methods [12][13][14][15]. This technique is thus an attractive approach for shipboard analysis of trace metals since LOV manifolds are compact, fully automated, and provide highly precise fluidic manipulations in a miniaturized flow manifold with minimal reagent consumption and waste production.…”
Section: Graphical Abstractmentioning
confidence: 99%
“…Further mixing is promoted by flow reversal, when the reaction mixture is propelled from HC1 towards the LOV flow cell for to monitor the fluorescence ( Figure 1D). In comparison to the sequencing of sample and reagent zones used in Sequential Injection LOV manifolds [12,14,16], the merging approach employed in this work increases the surface area of contact between the acidic…”
Section: Derivatization and Fluorescence Detection Optimizationmentioning
confidence: 99%
“…In recent years, FIA systems have evolved in ways that have led to the development of sequential injection analysis (SIA) systems. In this case, the injection of the sample and the contact with the reagent flow occur through the selection of the port of a central selector valve in which the mixture is provided with bi-directional movement, alternating the propulsion direction occurring in a single line, in the absence of confluences [2,8]. Due to these characteristics, SIA systems can be considered as differentiated from conventional FIA systems.…”
Section: Introductionmentioning
confidence: 99%
“…The possibility of exploiting feedback mechanisms to change sample processing conditions using a unique physical configuration make these approaches attractive to design flow procedures for process monitoring. 2,3 The characteristics of SIA enable automation of diverse operations such as sampling, chemical derivatization, dilution, standard addition and others, improving the reproducibility. Low sample and reagent consumption and small waste generation 4,5 are remarkable features of this technique, following the principles of green chemistry 6 applied to development of clean analytical methods.…”
Section: Introductionmentioning
confidence: 99%