A review of temperature-related challenges and solutions for the Abbott i-STAT and Siemens Healthineers epoc devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Consequently, our results are not generalizable for use in the provision of care during emergency medical services calls, critical care transport or disaster relief missions. Indeed, others recently reported that the analytical performances of the i-STAT Alinity POC system changed in an environment with extreme temperatures [29]. Additionally, we performed the PT and INR tests on a neutral purge tube, which could have flawed the results of the PT and INR measurements due to blood dilution and/or the activation of coagulation in the tube before the test.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequently, our results are not generalizable for use in the provision of care during emergency medical services calls, critical care transport or disaster relief missions. Indeed, others recently reported that the analytical performances of the i-STAT Alinity POC system changed in an environment with extreme temperatures [29]. Additionally, we performed the PT and INR tests on a neutral purge tube, which could have flawed the results of the PT and INR measurements due to blood dilution and/or the activation of coagulation in the tube before the test.…”
Section: Discussionmentioning
confidence: 99%
“…The following supporting information can be downloaded at: https:// www.mdpi.com/article/10.3390/diagnostics13020297/s1: Table S1: Review of the existing literature on the analytical performances of various Point-of-Care (POC) analyzers [2,4,7,12,21,22,[27][28][29][30][31][32][33][34][35][36][37][38].…”
Section: Supplementary Materialsmentioning
confidence: 99%
“…Manufacturers standardly issue requirements for operational and storage temperature and humidity. Exceeding these limits, even for brief periods of time, can render devices inoperable or produce clinically significant changes in POC test results [ 30 , 62 76 ]. This year, the International Federation of Clinical Chemistry Committee on POCT published guidelines for testing outside the hospital [ 77 ].…”
Section: Discussionmentioning
confidence: 99%
“…We hypothesized that there would be bias in the results of the POC devices compared to the results from the laboratory. This research was conducted in a tropical field setting where temperatures can exceed the operational temperature requirements of the POC devices, and various approaches have been described in the literature of ways to overcome such challenges [ 18 ]. Therefore, we further hypothesized that there would be differences in agreement based on study day due to daily differences in temperature.…”
Section: Introductionmentioning