A Review of Online Partial Discharge Measurement of Large Generators

Abstract: Abstract:Online partial discharge (PD) measurements have long been used as an effective means to assess the condition of the stator windings of large generators. An increase in the use of PD online measurement systems during the last decade is evident. Improvements in the detection capabilities are partly the reason for the increased popularity. Another reason has been the development of digital signal processing techniques. In addition, rapid progress is being made in automated single PD source classification… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
52
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 73 publications
(56 citation statements)
references
References 89 publications
(196 reference statements)
0
52
0
Order By: Relevance
“…The plot in Figure 8b gives-on the same time scale of Figure 8a-the average apparent charge per cycle q a (t) computed as per (3); here, the values of q a (t) have been normalized in the range [0, 1]. The plot in Figure 8c provides-on the same time scale of Figure 8a-the residuals referred to the linear regression computed on the data plotted in Figure 8 as per (4). As specified in Section 2 the linear regression is computed after removing the data belonging to the transient zone.…”
Section: Experimental Sessionmentioning
confidence: 99%
See 1 more Smart Citation
“…The plot in Figure 8b gives-on the same time scale of Figure 8a-the average apparent charge per cycle q a (t) computed as per (3); here, the values of q a (t) have been normalized in the range [0, 1]. The plot in Figure 8c provides-on the same time scale of Figure 8a-the residuals referred to the linear regression computed on the data plotted in Figure 8 as per (4). As specified in Section 2 the linear regression is computed after removing the data belonging to the transient zone.…”
Section: Experimental Sessionmentioning
confidence: 99%
“…A predictive maintenance apparatus monitors an electrical machine continuously to prevent a breakdown in the insulation system [1][2][3][4]. Electrical, mechanical and thermal stress sources systematically contribute to deteriorate motors.…”
Section: Introductionmentioning
confidence: 99%
“…They also have different coefficients of expansion. Severe vibration can introduce cracks inside the thick epoxy mica and voids inside the mica facilitating PDs [48][49][50][51][52][53][54][55][56]. Of course, winding temperature would depend on load which will show up in the temperature trending profile in an online monitoring configuration.…”
Section: Proposed Composite Damage Model For Gas-fired Generatorsmentioning
confidence: 99%
“…Partial discharge (PD) measurements have been made on electrical equipment insulation for many years and proved to be a sensitive means of insulation condition assessment and fault diagnosis [1][2][3][4][5][6][7]. However, electrical equipment operates in a strong electromagnetic environment, and PD on-line measurements are extremely affected and hampered by electrical noise [2].…”
Section: Introductionmentioning
confidence: 99%
“…A too large decomposition level will increase calculation complexity without significant improvement in the denoising effect; a too small decomposition level cannot achieve desirable denoising results. In previous studies, it was determined based on prior knowledge about signal energy distribution in the wavelet domain [6] or through trial and error [9][10][11], which is expert-dependent and subjective. Automatic approaches are introduced in references [17,19] aimed at guaranteeing that most energy of the signal is decomposed into detail sub-bands.…”
Section: Introductionmentioning
confidence: 99%