A Reliability-Exploitation Analysis of a Static Converter Taking Into Account Electromagnetic Interference

Abstract: The paper presents issues associated with the impact of electromagnetic interference on static converters, which exploitation in a railway transport environment. The measurements of an electromagnetic field emitted by a static converter were shown. Designs of this kind are exploitation in railway facilities, therefore, they should not disturb the functioning of other equipment, the rail traffic control systems, in particular. As a result of the EMC tests, it was concluded that the permissible values of conduct… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 40 publications
0
5
0
Order By: Relevance
“…The presence of these unfavorable phenomena within the operation process should already be taken into account at the ESS design stage. According to the article's authors and available source literature studies, there are no standards and legal requirements in this regard [60][61][62][63]. Proceeding with the design process requires prior testing of the electroclimate, including vibrations and noise [64][65][66][67].…”
Section: Overview Of Issues Related To Processes Associated With the ...mentioning
confidence: 99%
“…The presence of these unfavorable phenomena within the operation process should already be taken into account at the ESS design stage. According to the article's authors and available source literature studies, there are no standards and legal requirements in this regard [60][61][62][63]. Proceeding with the design process requires prior testing of the electroclimate, including vibrations and noise [64][65][66][67].…”
Section: Overview Of Issues Related To Processes Associated With the ...mentioning
confidence: 99%
“…There are additional filters inside the power supply, which eliminate interference occurring within a power mains-e.g., harmonics [94,99,100]. In addition, a power supply is equipped with overvoltage systems and filters reducing interference associated with ensuring FAS electromagnetic compatibility [96,101,102]. Unfitness or lack of main power supply is reported to an alarm-receiving-centre or service groups as a fail-safe (at that time, the system switches to backup power, e.g., from a battery bank) [96,[103][104][105].…”
Section: Energy Balance Determination Process Graph For Fas Operated ...mentioning
confidence: 99%
“…Paper [16] presents issues related to the impact of electromagnetic interference on track-side cabinets of closed-circuit television system operating in the railroad transport environment. The paper develops an operational model including electromagnetic interference.…”
Section: Introduction and Analysis Of The Issuementioning
confidence: 99%