1987
DOI: 10.1016/s0735-1097(87)80136-5
|View full text |Cite
|
Sign up to set email alerts
|

A reference data base for multilead electrocardiographic computer measurement programs

Abstract: In an effort to standardize and evaluate the performance of electrocardiographic computer measurement programs, a 15 lead reference library has been developed based on simultaneously recorded standard 12 lead and orthogonal XYZ lead data. A set of 250 electrocardiograms (ECGs) with selected abnormalities was analyzed by a group of five referee cardiologists and 11 different 12 lead and 6 XYZ computer programs. Attention was focused on the exact determination of the onsets and offsets of P, QRS and T waves. The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
80
0
2

Year Published

1992
1992
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 140 publications
(83 citation statements)
references
References 8 publications
1
80
0
2
Order By: Relevance
“…The MEANS program has been evaluated extensively and has been validated (Willems et al 1987, van Bemmel et al 1990, de Bruyne et al 1997. In one of these validation studies, ECGs with selected abnormalities were analyzed by 5 cardiologists and 11 different computer programs of which MEANS performed as one of the best (Willems et al 1987) In another validation study in which QT intervals by manual measurement were compared with those generated by ECG machines, manual and automated measurements generated similar numerical results in three studies in healthy volunteers, which all included a positive control (Darpo et al 2006). MEANS determines common onsets and offsets for all 12 leads together on one representative averaged beat, with the use of template matching techniques (van Bemmel et al 1990).…”
Section: Qtc Prolongationmentioning
confidence: 99%
“…The MEANS program has been evaluated extensively and has been validated (Willems et al 1987, van Bemmel et al 1990, de Bruyne et al 1997. In one of these validation studies, ECGs with selected abnormalities were analyzed by 5 cardiologists and 11 different computer programs of which MEANS performed as one of the best (Willems et al 1987) In another validation study in which QT intervals by manual measurement were compared with those generated by ECG machines, manual and automated measurements generated similar numerical results in three studies in healthy volunteers, which all included a positive control (Darpo et al 2006). MEANS determines common onsets and offsets for all 12 leads together on one representative averaged beat, with the use of template matching techniques (van Bemmel et al 1990).…”
Section: Qtc Prolongationmentioning
confidence: 99%
“…From each lead, the average complex was calculated by the MEANS (Modular ECG Analysis) system.22. 23 Individual averaged complexes were stored digitally. Standard criteria were used to diagnose ECG-documented LVH?4…”
Section: Twelve-lead Surface Electrocardiogrammentioning
confidence: 99%
“…Then, for each individual lead, a form of second derivative of the signal is used to locate the definitive T end. On the basis of a comparison with other programs published in 1987, 21 Given the availability of orthogonal XYZ leads, it is possible to derive the 12-lead ECG from these leads by the use of generally accepted equations. 22 For example, at any sampling instant, lead I can be derived as follows:…”
Section: Computerized Ecg Analysismentioning