2022
DOI: 10.1109/tasc.2022.3140688
|View full text |Cite
|
Sign up to set email alerts
|

A Reel-to-Reel Scanning Hall Probe Microscope for Characterizing Long REBCO Conductor in Magnetic Fields Up to 5 Tesla

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Such an approach disregards possible lateral distribution of the defects causing local I c reductions that has been revealed in magnetic mapping, optical scanning and Raman spectroscopy [9][10][11][12][13]. It is also clear that defects in different lateral positions could have different impacts on the Tapestar results and on the tape performance [14][15][16]. Nevertheless, in the experiments observing bubble creation in a nitrogen bath, it was found that the overheated zones appear in strips crossing the full width of the tape, probably because of current congestion around defects [17,18].…”
Section: Methodology Used For Analyzing the Datamentioning
confidence: 99%
“…Such an approach disregards possible lateral distribution of the defects causing local I c reductions that has been revealed in magnetic mapping, optical scanning and Raman spectroscopy [9][10][11][12][13]. It is also clear that defects in different lateral positions could have different impacts on the Tapestar results and on the tape performance [14][15][16]. Nevertheless, in the experiments observing bubble creation in a nitrogen bath, it was found that the overheated zones appear in strips crossing the full width of the tape, probably because of current congestion around defects [17,18].…”
Section: Methodology Used For Analyzing the Datamentioning
confidence: 99%
“…SHM is well positioned to study these materials due to its quantitative nature, as well as its variable temperature operation from milli-Kelvin temperatures to well above the highest cuprate T c . By mapping the pinning of vortices to defect sites as well as quantitatively measuring the temperature dependent vortex profiles, SHM provides critical feedback for the optimisation of flux pinning [122,[147][148][149]. The miniaturisation of Hall probes down to the nanoscale using graphene will enable an expansion of this research by improving the correlation between vortices and nanoscale pinning sites.…”
Section: Current and Future Use Of The Technique For Materials Sciencementioning
confidence: 99%
“…The critical current fits are reported in table 3. data is available for each tape [11,12], knowledge of the spatial distribution of local reductions in critical current density can be used to inform layering strategies. In this section, the network model is coupled with an optimization algorithm to recommend the optimal placement and orientation of tapes with defects within a cable.…”
Section: Optimal Defect Sortingmentioning
confidence: 99%
“…Research has been reported on performance degradation throughout the ReBCO life cycle. The field of individual tape characterization is mature, and high-throughput methods are available to measure the spatial variation of tape performance [11,12]. Several models have been developed to study the mechanics of tape cabling and bending [13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%