A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System

Abstract: BackgroundFor reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system.MethodsThe N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
151
3

Year Published

2012
2012
2017
2017

Publication Types

Select...
8
1

Relationship

6
3

Authors

Journals

citations
Cited by 102 publications
(160 citation statements)
references
References 35 publications
(38 reference statements)
5
151
3
Order By: Relevance
“…Nitrogen multiple-breath washout All children performed nitrogen MBW (N 2 MBW) according to current consensus [25] using a previously described setup [26,27] (Exhalyzer D; Eco Medics AG). The application of 100% oxygen washes out the lung-resident nitrogen.…”
Section: Assessment Of Respiratory Symptoms and Atopic Sensitisation mentioning
confidence: 99%
“…Nitrogen multiple-breath washout All children performed nitrogen MBW (N 2 MBW) according to current consensus [25] using a previously described setup [26,27] (Exhalyzer D; Eco Medics AG). The application of 100% oxygen washes out the lung-resident nitrogen.…”
Section: Assessment Of Respiratory Symptoms and Atopic Sensitisation mentioning
confidence: 99%
“…The reference lung function test was MBNW performed using validated equipment [18], according to guidelines [17] and is detailed in the online supplementary material. Primary outcome was LCI calculated as the ratio of cumulative expired volume divided by functional residual capacity [19,20].…”
Section: Multiple-breath Nitrogen Washoutmentioning
confidence: 99%
“…Investigators report differing findings for the inter-test reproducibility of the LCI due to variability in protocol designs, study population and MBW methodology [5][6][7][8][9][10][11][12][13][14]. Most notably, time intervals between repeated tests range from hours to years, and none report reproducibility for time intervals typically used to clinically track patients with cystic fibrosis (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…Most notably, time intervals between repeated tests range from hours to years, and none report reproducibility for time intervals typically used to clinically track patients with cystic fibrosis (e.g. quarterly) [6,11,15]. Comparison between studies is further limited by the various methodologies that define reproducibility; coefficient of variation (%CV) [5,7,8], the intra-class correlation coefficient (ICC) [6], the limits of agreement from Bland-Altman plots [5,[9][10][11] or the coefficient of reproducibility [12,13].…”
Section: Introductionmentioning
confidence: 99%