A Real Time Approach: ECG Noise Reduction in Chebyshev Type II Digital Filter

Abstract: It is well known that biomedical signals carry important information about the behavior of the living systems under study. With the analysis of the Electrocardiogram (ECG) signal it may be possible to predict heart problems or monitor patient recovery after a heart intervention. A proper processing of these signals enhances their physiological and clinical information. The quality of biomedical signal is degraded mainly by many sources of noise such as power line interference (PLI), baseline drift, muscle cont… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…GA makes the magnitude response corresponding to the transfer function shown in Equation (10) approximate Equation (9), that is, minimizes the cumulative sum of the squares of the magnitude response errors of both of them, and the values of the parameters a 0 , a 1 , and a 2 can be obtained by using Equation (11):…”
Section: Optimal Designmentioning
confidence: 99%
See 3 more Smart Citations
“…GA makes the magnitude response corresponding to the transfer function shown in Equation (10) approximate Equation (9), that is, minimizes the cumulative sum of the squares of the magnitude response errors of both of them, and the values of the parameters a 0 , a 1 , and a 2 can be obtained by using Equation (11):…”
Section: Optimal Designmentioning
confidence: 99%
“…According to the GA flow chart shown in Figure 7 and the GA control parameters in Table 1, the relevant program is executed, and the running time is 366.2 s (Running Environment: Intel(R) Core (TM) i7-8550U CPU @ 1.80GHz, RAM 16G, Windows 10, Python 3.9.5), the optimized parameter values in Equation ( 10) can be obtained using Equation (11), and the optimized parameter values are shown in Table 2.…”
Section: Optimal Designmentioning
confidence: 99%
See 2 more Smart Citations
“…Chebyshev Type II has no ripple in the passband, but does have equiripple in the stopband. Inverse Chebyshev filters are also called Type II Chebyshev filter [31,32]. The gain is…”
Section: 23chebyshev Type II Filtermentioning
confidence: 99%