2018
DOI: 10.1016/j.apradiso.2018.02.008
|View full text |Cite
|
Sign up to set email alerts
|

A rapid method for the sequential separation of polonium, plutonium, americium and uranium in drinking water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(2 citation statements)
references
References 18 publications
0
2
0
Order By: Relevance
“…The complete MinION data can be further analyzed and polished after the entire sequencing run to obtain accurate, whole genomes that provide detailed data on subtyping, virulence genes, antimicrobial resistance genes, and other genetic characteristics. Same-day detection of antimicrobial resistance genes with 99.75% accuracy (with polishing) after enriching for plasmid DNA and MinION sequencing has been recently demonstrated 47 . Here, we also demonstrate the potential of the un-polished, MinION-only results for rapid phylogenetic inference with identical topology as compared to the reference published dataset after only 30 mins of sequencing, with consistent results at all other analyzed time points.…”
Section: Discussionmentioning
confidence: 99%
“…The complete MinION data can be further analyzed and polished after the entire sequencing run to obtain accurate, whole genomes that provide detailed data on subtyping, virulence genes, antimicrobial resistance genes, and other genetic characteristics. Same-day detection of antimicrobial resistance genes with 99.75% accuracy (with polishing) after enriching for plasmid DNA and MinION sequencing has been recently demonstrated 47 . Here, we also demonstrate the potential of the un-polished, MinION-only results for rapid phylogenetic inference with identical topology as compared to the reference published dataset after only 30 mins of sequencing, with consistent results at all other analyzed time points.…”
Section: Discussionmentioning
confidence: 99%
“…210 Po 4+ adsorbed to extraction chromatography resin together with the transuranium isotope ions can be removed before eluting Pu, Am and Cm. For example, 210 Po can be removed using 8 M HNO 3 from TRU column before eluting Am + Cm [51] and also with 8 M HNO 3 from TEVA column [52]. It is also possible to elute Pu from a TRU column with a solution containing the reducing reagent TiCl 3 , instead of more commonly used ammonium oxalate solution, for keeping any residual tetravalent 210 Po 4+ in the resin column while eluting trivalent Pu 3+ [53].…”
Section: Future Aims For the Radioanalytical Developmentmentioning
confidence: 99%