1993
DOI: 10.1093/jat/17.4.218
|View full text |Cite
|
Sign up to set email alerts
|

A Rapid Gas Chromatographic Method for Determination of Ethylene Glycol in Serum and Urine

Abstract: Intoxications with the antifreeze constituent ethylene glycol (EG) occur infrequently, but may be fatal if not recognized and treated promptly. The aim of the present work was to develop an analytical method for rapid diagnosis of EG poisoning and for monitoring EG removal by hemodialysis. EG was measured by gas chromatography upon direct injection of serum or urine samples (50 microL diluted in 200 microL of distilled water containing 2,3-butanediol as internal standard). A 2-m x 2-mm glass column with Chromo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
7
0
1

Year Published

2001
2001
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(9 citation statements)
references
References 16 publications
1
7
0
1
Order By: Relevance
“…When the analysis is performed with a commonly used capillary column, it appears to be free from known interferences (Porter et al 1994). Other methods such as those based on direct injection may be subject to carryover (Aarstad et al 1993) or significant interferences from physiological substances, for example, propionic acid (present in methylmalonic acidema; Shoemaker et al 1992) and 2,3-butanediol (present in serum from alcoholic patients; Jones et al 1991).…”
Section: Methodsmentioning
confidence: 99%
“…When the analysis is performed with a commonly used capillary column, it appears to be free from known interferences (Porter et al 1994). Other methods such as those based on direct injection may be subject to carryover (Aarstad et al 1993) or significant interferences from physiological substances, for example, propionic acid (present in methylmalonic acidema; Shoemaker et al 1992) and 2,3-butanediol (present in serum from alcoholic patients; Jones et al 1991).…”
Section: Methodsmentioning
confidence: 99%
“…3,4,6 Gas chromatography (GC) is considered the gold standard method for quantitative measurement of EG levels in serum or plasma. 14,15 However, the availability of GC is limited and results may not be obtainable within a clinically useful timeframe.…”
Section: Abbreviationsmentioning
confidence: 99%
“…There are some analytical methods to determine EG with gas and liquid chromatography. In gas chromatography coupled with flame ionization detector, EG could be analyzed by direct injection [4], but the risk is the misinterpretation of interfering peaks. In liquid chromatography coupled with tandem mass spectrometry, direct analysis has the problem because of the small molecular mass, which leads to the low signal and high detection limit [5], indirect analysis with benzoyl chloride has advanced [6].…”
Section: Introductionmentioning
confidence: 99%