The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2007
DOI: 10.1016/j.ijoa.2006.07.004
|View full text |Cite
|
Sign up to set email alerts
|

A randomized trial of crystalloid versus colloid solution for prevention of hypotension during spinal or low-dose combined spinal-epidural anesthesia for elective cesarean delivery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
1
1

Year Published

2007
2007
2013
2013

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 57 publications
(29 citation statements)
references
References 31 publications
(34 reference statements)
0
22
1
1
Order By: Relevance
“…1 This has been attributed in part to local anesthetic-induced sympathectomy and in part to aortocaval compression caused by the gravid uterus. Several strategies, including uterine displacement, 2 lower legs compression, 3 and the administration of fluids 4 and vasopressors, 5 have been shown to decrease the occurrence of this hypotension; however, none has been shown to eliminate the need to treat it. 6 In contrast, patient position has had variable effects on the incidence of hypotension after spinal anesthesia.…”
Section: Introductionmentioning
confidence: 99%
“…1 This has been attributed in part to local anesthetic-induced sympathectomy and in part to aortocaval compression caused by the gravid uterus. Several strategies, including uterine displacement, 2 lower legs compression, 3 and the administration of fluids 4 and vasopressors, 5 have been shown to decrease the occurrence of this hypotension; however, none has been shown to eliminate the need to treat it. 6 In contrast, patient position has had variable effects on the incidence of hypotension after spinal anesthesia.…”
Section: Introductionmentioning
confidence: 99%
“…20,24 Colloid preload (regimen II) Usually, colloid preloading appears to be effective in preventing arterial hypotension and maintaining maternal cardiac output, compared with crystalloid preloading or no preloading at all. 7,11,18,[25][26][27][28][29] Siddik et al showed that giving a volume of 500 mL of hydroxyethyl starch decreased hypotension, the requirement for vasopressors, and the incidence of nausea and vomiting, compared with 1,000 mL of Ringer's lactate. 28 In a study by Dahlgren et al, patients who received 1,000 mL of 3% dextran had fewer hypotensive episodes associated with nausea and vomiting.…”
Section: Intravascular Volume Loading Strategiesmentioning
confidence: 99%
“…7,11,18,[25][26][27][28][29] Siddik et coll. ont démontré que l'administration d'un volume de 500 mL d'hydroxyéthylamidon réduisait l'incidence d'hypotension, les besoins en vasopresseurs et l'incidence de nausées et vomissements comparativement à un volume de 1,000 mL de lactate Ringer.…”
Section: Les Stratégies De Remplissage Vasculaireunclassified
“…[3] With the recent focus is on the timing of fluid bolus (preload or coload) and the viability of colloids, we chose to compare the relative efficacy of colloid preload versus coload in reduction of hypotension during cesarean delivery, under the settings of low dose spinal anesthesia.…”
Section: Introductionmentioning
confidence: 99%