Abstract: Aims Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. Patients and Methods We … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
32
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(35 citation statements)
references
References 29 publications
2
32
1
Order By: Relevance
“…Five other RCT shave compared vE-PE and XLPE liner wear. 16 - 20 Two trials report no difference at two or seven years, respectively, while three trials report lower wear in vE-PE liners at five, five, and seven years, respectively. All these studies use the same RSA setup as this study.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…Five other RCT shave compared vE-PE and XLPE liner wear. 16 - 20 Two trials report no difference at two or seven years, respectively, while three trials report lower wear in vE-PE liners at five, five, and seven years, respectively. All these studies use the same RSA setup as this study.…”
Section: Discussionmentioning
confidence: 96%
“… 13 This material has shown increased resistance to oxidation and fatigue crack propagation, as well as a low wear rate in experimental settings and has been investigated in vivo. 14 - 20 …”
Section: Introductionmentioning
confidence: 99%
“…Promising results by clinical trials in uncemented cups 18 , 19 and some concerns in cemented cups suggest that registry monitoring will be key for these components in the future. 20 …”
Section: Discussionmentioning
confidence: 99%
“…Since vitamin E-infused highly crosslinked polyethylene (VEPE) is a quite recent invention, there are only short-and mid-term data available on its efficacy and safety. Significantly lower femoral head penetration rates have been reported for VEPE liners by many authors in randomized controlled trials (RCTs) with radiostereometric analysis (RSA) compared with HXLPE liners (Nebergall et al 2017, Scemama et al 2017, Shareghi et al 2017, Galea et al 2018, Rochcongar et al 2018, Sköldenberg et al 2019. However, there is still a lack of real-world data from arthroplasty registers on the survival of VEPE liners.…”