2005
DOI: 10.1111/j.1365-2044.2005.04330.x
|View full text |Cite
|
Sign up to set email alerts
|

A randomised comparison of the Portex Softseal laryngeal mask airway with the LMA‐Unique during anaesthesia

Abstract: Summary We have compared the performance of the single use laryngeal airway devices Softseal™ and LMA‐Unique™ in a randomised comparative trial in anaesthetised healthy patients who did not receive neuromuscular blockade. Primary outcome was success of airway placement. Secondary outcomes included manipulations and complications during use, ease of insertion, airway and fibreoptic assessment of airway positioning, and complications postoperatively. We planned to study 300 patients but interim analysis demonstr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
18
0
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(23 citation statements)
references
References 21 publications
(36 reference statements)
4
18
0
1
Order By: Relevance
“…The OLP values observed in our study were similar to those found in the studies of López et al (12), van Zundert et al (29), and Cook et al (30) when the cuff inner pressure was maintained at 60 cmH 2 O, i.e. 22 ± 6, 25 ± 6, and 20.5 cmH 2 O, respectively.…”
Section: Discussionsupporting
confidence: 81%
“…The OLP values observed in our study were similar to those found in the studies of López et al (12), van Zundert et al (29), and Cook et al (30) when the cuff inner pressure was maintained at 60 cmH 2 O, i.e. 22 ± 6, 25 ± 6, and 20.5 cmH 2 O, respectively.…”
Section: Discussionsupporting
confidence: 81%
“…Clinical comparisons of the LMA Unique and Soft Seal have been reported by Brimacombe et al [16], Cook et al [18], and Paech et al [17], and all of the investigators found that the LMA Unique was the easier to insert in expert hands. In contrast, van Zundert et al [23] found no differences between the LMA Unique and Soft Seal when compared with the CobraPLA.…”
Section: Discussionmentioning
confidence: 91%
“…3). Some studies have assessed its clinical performance compared with that of the LMA Classic [12][13][14][15] and the LMA Unique [16][17][18], with varying results. The Solus has the same sizes and design as the LMA Unique, except without epiglottic bars (Solus Laryngeal Mask Airway information sheet; Intersurgical, Ltd), but it has a harder cuff.…”
Section: Introductionmentioning
confidence: 98%
“…First-time insertion success with the SSLM have been reported to range from 62% [13] to 95% [1,14], and overall success from 90% [15] to 100% [1, 16,17]. Insertion times for the SSLM ranges between 20 s [4] and 50 s [13].…”
Section: ó 2008 the Authorsmentioning
confidence: 99%