2020
DOI: 10.4103/ija.ija_313_20
|View full text |Cite
|
Sign up to set email alerts
|

A randomised comparative study of “videoendoscope” with the Truview EVO2, C-MAC D blade videolaryngoscope and the Macintosh laryngoscope

Abstract: Background and Aims: Videolaryngoscopes are crucial components of a difficult airway cart. Issues of cost and availability, however, remain a problem. We compared the combination of an endoscope used in conjunction with the Macintosh laryngoscope with established videolaryngoscopes and the Macintosh laryngoscope using the intubation difficulty scale (IDS) score. Materials and Methods: A prospective randomised study including 120 adult patients, American Society of Anaes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(24 citation statements)
references
References 17 publications
0
22
0
Order By: Relevance
“…Another 7 studies although had proposed a novel form of videolaryngoscope in the title, were not customised form for use [ 15 21 ] Other 5 studies out of 21 were editorials, case series, letters to editors with no human participation involved and with no intervention [ 4 , 22 25 ]. The remaining five studies were eligible and contained data with intervention performed in the patients [ 6 , 26 29 ]. Out of five, only three studies had a comparison group [ 26 – 28 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Another 7 studies although had proposed a novel form of videolaryngoscope in the title, were not customised form for use [ 15 21 ] Other 5 studies out of 21 were editorials, case series, letters to editors with no human participation involved and with no intervention [ 4 , 22 25 ]. The remaining five studies were eligible and contained data with intervention performed in the patients [ 6 , 26 29 ]. Out of five, only three studies had a comparison group [ 26 – 28 ].…”
Section: Resultsmentioning
confidence: 99%
“…The remaining five studies were eligible and contained data with intervention performed in the patients [ 6 , 26 29 ]. Out of five, only three studies had a comparison group [ 26 – 28 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…23 Even videoendoscope have comparable results with C MAC VL D blade and found superior to Truview EVO 2 and DL in anticipated difficult airway and provides a cheaper alternative to VL. 24 Regarding limitations in our study, we chose MMC alone to predict difficult intubations which might have lead to subjective variations. Though MMC III and IV holds good for the prediction of difficult intubation, it has high number of false positive ratings and a low predictive value.…”
Section: Discussionmentioning
confidence: 99%