2021
DOI: 10.1016/j.talanta.2021.122555
|View full text |Cite
|
Sign up to set email alerts
|

A quantitative UHPLC-MS/MS method for the growth hormone-releasing peptide-6 determination in complex biological matrices and transdermal formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 52 publications
0
3
0
Order By: Relevance
“…From the perspective of analytical chemistry, MNs sampling coupled with chromatography‐mass spectrometry may contribute to the resolution of the above question, although limited examples have been identified so far. [ 94,95 ]…”
Section: Microneedles (Mns) For Transdermal Diagnosismentioning
confidence: 99%
See 1 more Smart Citation
“…From the perspective of analytical chemistry, MNs sampling coupled with chromatography‐mass spectrometry may contribute to the resolution of the above question, although limited examples have been identified so far. [ 94,95 ]…”
Section: Microneedles (Mns) For Transdermal Diagnosismentioning
confidence: 99%
“…From the perspective of analytical chemistry, MNs sampling coupled with chromatography-mass spectrometry may contribute to the resolution of the above question, although limited examples have been identified so far. [94,95] MNs, as the delivery tool, are used to inject diagnostic agents such as fluorescent or colorimetric probe into the skin dermal layer. [86][87][88][89] For instance, the colorimetric sensing reagents encapsulated in dissolving MNs are delivered in ISF to construct colorimetric tattoo biosensor.…”
Section: Microneedles (Mns) For Transdermal Diagnosismentioning
confidence: 99%
“…The more accurate and reliable results from this system make MS technology more widely applied in cosmetic and topical drug research. Many new delivery systems such as microneedle [48], Colloidal nanodispersions [49], Polymeric micelle mediated follicular [50], Sulfhydryl modified polymers [51], and polyamidoamine dendrimers [52] have been evaluated with MS technologies. In addition, LCMS is a very quick and effective tool to determine AI for skin benefits and a great linkage between traditional raw materials from botanical and food resources and skin efficacy validation [53].…”
Section: Mass Spectrometry Technologymentioning
confidence: 99%
“…In the case of well-equipped high-end instruments (especially HRMS instruments), there are no issues in finding concentrations below 1 ng/mL. The main issue with such compounds is their stability and the excretion time in urine [14][15][16]. The main sample preparation technique for such compounds, like GHRP-2 and GHRP-6, is solid-phase extraction on SCX or WCX sorbents of different volumes.…”
Section: Introductionmentioning
confidence: 99%
“…The main sample preparation technique for such compounds, like GHRP-2 and GHRP-6, is solid-phase extraction on SCX or WCX sorbents of different volumes. Such sample preparation can be used for significant pre-concentration of the sample and its cleanup [14].…”
Section: Introductionmentioning
confidence: 99%