2008
DOI: 10.1111/j.1365-2044.2008.05489.x
|View full text |Cite
|
Sign up to set email alerts
|

A quantitative review and meta‐analysis of performance of non‐standard laryngoscopes and rigid fibreoptic intubation aids

Abstract: SummaryThis quantitative review summarises studies of rigid fibreoptic laryngoscopy systems. In 6622 'normal' patients only the Bonfils and CTrach had homogenous data and first time intubation success rates above 90%. In 1110 patients predicted or known to be difficult to intubate only the Bonfils, CTrach and Glidescope had homogenous data and first-time success rates above 90%. In comparative studies with the Macintosh-3 blade, no device had homogenous data in more than one study. Many devices had higher summ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
125
1
3

Year Published

2009
2009
2016
2016

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 152 publications
(134 citation statements)
references
References 87 publications
5
125
1
3
Order By: Relevance
“…15 Only the Bonfils TM (Karl Storz Co, Tuttlingen, Germany) and CTrach TM (The Laryngeal Mask Company Ltd, Jersey, Channel Islands) had homogenous data and first-time intubation success rates above 90% in normal patients. The Bonfils TM , CTrach TM and Glidescope TM (Verathon Medical ULC, Burnaby, Canada) had first-time success rates above 90% in patients predicted or known to be difficult to intubate.…”
Section: Evaluation Of New and Alternative Technologies For Difficultmentioning
confidence: 99%
“…15 Only the Bonfils TM (Karl Storz Co, Tuttlingen, Germany) and CTrach TM (The Laryngeal Mask Company Ltd, Jersey, Channel Islands) had homogenous data and first-time intubation success rates above 90% in normal patients. The Bonfils TM , CTrach TM and Glidescope TM (Verathon Medical ULC, Burnaby, Canada) had first-time success rates above 90% in patients predicted or known to be difficult to intubate.…”
Section: Evaluation Of New and Alternative Technologies For Difficultmentioning
confidence: 99%
“…New rigid fibrescopes have been used as alternatives to a flexible bronchoscope [8]. The Clarus Video System (CVS; Clarus Medical, Minneapolis, MN, USA) [9] consists of a rechargeable battery, adjustable monitor and malleable stylet, that can be preloaded with a tracheal tube (Fig.…”
mentioning
confidence: 99%
“…We would like to thank Drs Maloney and Walker for bringing to our attention the series published by the Galway group comparing the Macintosh and the Airtraq laryngoscopes [1][2][3][4][5].…”
Section: A Replymentioning
confidence: 99%
“…It is commonplace to attend the trade show at conferences and expensive airway workshops, which usually make extensive use of manikins, many of which have almost no relevance to clinical use. Manikins for supraglottic airway insertion [4] and management of difficult intubation [5] are a particular problem.…”
Section: A Replymentioning
confidence: 99%