2016
DOI: 10.1088/0952-4746/36/3/391
|View full text |Cite
|
Sign up to set email alerts
|

A puzzling case of contamination with241Am

Abstract: Two people were exposed to and contaminated with Am. In vivo determinations of the incorporatedAm were performed using a whole-body counter and two partial-body counters for the skull and lung, respectively. Additionally, urine samples were analysed to estimate the systemic activity removed from the body. To improve the geometry of the skull measurements, an optimised detector configuration was used, a calibration with three physical phantoms of the human head was conducted, and the morphological variability b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…The detector model was implemented in Geant4 using the constructive solid geometry (CSR) module. Skull phantoms were implemented in Voxel geometry using the G4Phantom Parameterisation (Garny 2009).…”
Section: Geant4mentioning
confidence: 99%
“…The detector model was implemented in Geant4 using the constructive solid geometry (CSR) module. Skull phantoms were implemented in Voxel geometry using the G4Phantom Parameterisation (Garny 2009).…”
Section: Geant4mentioning
confidence: 99%
“…In conclusion, a lot of research need to develop new systems to detect a prompt accident and construct integrated biokinetics models of retrospective dosimetry in case of radioactive isotopes intake [11].…”
Section: Dear Editormentioning