2020
DOI: 10.14326/abe.9.167
|View full text |Cite
|
Sign up to set email alerts
|

A Prototyping of Penile Tumescence Continuous Observation Device

Abstract: In this study, we attempted to develop a wireless real-time continuous observation device for penile tumescence and/or stiffness for veri cation of nocturnal penile tumescence (NPT) and for diagnosis and classi cation of erectile dysfunction (ED). Unlike conventional mechanically wired method, the patient is not constrained by the device and is able to use the device by himself in his own living environment. A soft silicone ring that ts the penis is equipped with a built-in variable inductance, variable freque… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 4 publications
0
1
0
Order By: Relevance
“…(D) The room temperature vulcanizing (RTV) soft silicon ring with oscillator circuit board and battery moulded in the ring with a background of 1 cm/1 mm grid paper. Reproduced with permission from ref 65 . Copyright 2020, Advanced Biomedical Engineering.…”
Section: Monitoring Of Ed Using Smart Wearables and Digital Technologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…(D) The room temperature vulcanizing (RTV) soft silicon ring with oscillator circuit board and battery moulded in the ring with a background of 1 cm/1 mm grid paper. Reproduced with permission from ref 65 . Copyright 2020, Advanced Biomedical Engineering.…”
Section: Monitoring Of Ed Using Smart Wearables and Digital Technologiesmentioning
confidence: 99%
“…In their pursuit of creating a wireless and continuous monitoring device, Matsumoto et al developed a wearable system consisting of a flexible silicon ring (Figure 2D). 65 The innovative system is constructed using RTV (room temperature vulcanizing) soft silicone gel and incorporates components such as a variable inductance, variable frequency oscillator and a disposable micro‐battery. The primary parameter under measurement is penile circumferences, which is represented by the lateral tension applied to the soft silicon ring.…”
Section: Monitoring Of Ed Using Smart Wearables and Digital Technologiesmentioning
confidence: 99%
“…There have been several attempts to develop a real-time ED diagnosis device that can be privately operated in the comfort of the patient home [ 14 ]. Similarly, for the diagnostic evaluation of ED, there are attempts to investigate using different diagnostic methods such as Doppler ultrasonography and shear wave elastography to better evaluate ED or penile rigidity instead of using the traditional RigiScan ® device [ 15 , 16 ].…”
Section: Introductionmentioning
confidence: 99%