2019
DOI: 10.1016/j.nima.2019.06.023
|View full text |Cite
|
Sign up to set email alerts
|

A prototype system for dynamically polarized neutron protein crystallography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Measuring at higher proton polarization would give greater differences in peak intensities between different spin configurations, and improved neutron count rates would provide statistical significance in the analysis to determine jF H ðQÞj 2 and Re½F H ðQÞF others ðQÞ Ã . Although the opening angle of the neutron windows of approximately 120 of the new DNP apparatus is smaller than that used in previous studies [210 (Piegsa et al, 2013) and 360 (Pierce, 2017;Pierce et al, 2019)], the pulsed neutron measurements with the new DNP apparatus in J-PARC MLF seamlessly cover the Q range up to approximately 10 Å À1 . In addition, a 3 He neutron spin filter that polarizes neutrons with less than 1.0 Å was recently developed and installed in a crystal diffractometer whose resolving power is higher than that of TAIKAN (Okudaira et al, 2020).…”
Section: Discussionmentioning
confidence: 86%
“…Measuring at higher proton polarization would give greater differences in peak intensities between different spin configurations, and improved neutron count rates would provide statistical significance in the analysis to determine jF H ðQÞj 2 and Re½F H ðQÞF others ðQÞ Ã . Although the opening angle of the neutron windows of approximately 120 of the new DNP apparatus is smaller than that used in previous studies [210 (Piegsa et al, 2013) and 360 (Pierce, 2017;Pierce et al, 2019)], the pulsed neutron measurements with the new DNP apparatus in J-PARC MLF seamlessly cover the Q range up to approximately 10 Å À1 . In addition, a 3 He neutron spin filter that polarizes neutrons with less than 1.0 Å was recently developed and installed in a crystal diffractometer whose resolving power is higher than that of TAIKAN (Okudaira et al, 2020).…”
Section: Discussionmentioning
confidence: 86%
“…These results were consistent across all of the samples, and are also consistent with the assumed 50% initial polarization. A more thorough discussion of the results of these tests (including diffraction plots) can be found in references [4] and [10]…”
Section: First Resultsmentioning
confidence: 99%
“…A prototype system for the purpose of polarizing protein crystals has been constructed and commissioned at ORNL. A full description of the device can be found in Reference [4]. A brief summary is included here.…”
Section: Apparatusmentioning
confidence: 99%
See 2 more Smart Citations