2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134)
DOI: 10.1109/pess.2000.867423
|View full text |Cite
|
Sign up to set email alerts
|

A prototype self-tuning adaptive power system stabilizer for damping of active power swings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…Many examples with utilization of different adaptive techniques for realization of PSS can be found in publications. The majority of PSS realizations are based on usage of indirect adaptive control, where explicit identification of a mathematical model of a synchronous generator is needed to be carried out [16,17]. A transparent structure of the adaptive control system with the separated identification algorithm and the control law represents an advantage of indirect adaptive PSS.…”
Section: Adaptive Pssmentioning
confidence: 99%
“…Many examples with utilization of different adaptive techniques for realization of PSS can be found in publications. The majority of PSS realizations are based on usage of indirect adaptive control, where explicit identification of a mathematical model of a synchronous generator is needed to be carried out [16,17]. A transparent structure of the adaptive control system with the separated identification algorithm and the control law represents an advantage of indirect adaptive PSS.…”
Section: Adaptive Pssmentioning
confidence: 99%
“…A commercial version of the adaptive power system stabilizer (APSS), using recursive least squares (RLS) identification and pole-shift (PS) controller has been implemented and tested in the field [7].…”
Section: Introductionmentioning
confidence: 99%
“…There exist noise and saturation of elements as well as unexpected disturbances that cause the power system to operate under a continuous small perturbation. Generally, it is necessary to do laboratory [14] and field tests [7] prior to assessing the performance of the adaptive PSS (APSS) on an actual system [15,16].…”
Section: Introductionmentioning
confidence: 99%
“…After that, the identified mathematical model is used to calculate the parameters of the controller (Eichmann, 2000).…”
mentioning
confidence: 99%
“…• Indirect methods, where one of the parametric identification methods is used to identify the parameters of a mathematical model of the controlled plant. After that, the identified mathematical model is used to calculate the parameters of the controller (Eichmann, 2000).…”
mentioning
confidence: 99%