2016
DOI: 10.1016/j.jacr.2016.02.030
|View full text |Cite
|
Sign up to set email alerts
|

A Prostate Fossa Contouring Instructional Module: Implementation and Evaluation

Abstract: Purpose/Objective Radiation oncology trainees frequently learn to contour through clinical experience and lectures. A hands-on contouring module was developed to teach delineation of the postoperative prostate clinical target volume (CTV) and improve contouring accuracy. Methods Medical students independently contoured a prostate fossa CTV before and after receiving educational materials and live instruction detailing the RTOG approach to contouring this CTV. Metrics for volume overlap and surface distance (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 14 publications
(20 reference statements)
0
8
0
Order By: Relevance
“…It provides values between 0 and 1, where 0 represents no intersection and 1 reflects clear overlap of structures A and B. In the literature, a DSC > 0.7 is commonly reported to indicate an excellent match . The DSC parameter not only considers absolute volumes but also local positions of two (A and B) compared volumes.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It provides values between 0 and 1, where 0 represents no intersection and 1 reflects clear overlap of structures A and B. In the literature, a DSC > 0.7 is commonly reported to indicate an excellent match . The DSC parameter not only considers absolute volumes but also local positions of two (A and B) compared volumes.…”
Section: Methodsmentioning
confidence: 99%
“…In the literature, a DSC > 0.7 is commonly reported to indicate an excellent match. 24 The DSC parameter not only considers absolute volumes but also local positions of two (A and B) compared volumes. Single absolute volumes of two structures are independent of the location.…”
Section: Methodsmentioning
confidence: 99%
“…The CT HR-CTV and MRI HR-CTV were then superimposed on one another, and the Dice coefficient of similarity (DC) was calculated using the formula DCfalse(A,Bfalse)=2|AB||A|+|B|, where A represents the CT HR-CTV contour, B represents the MRI HR-CTV contour, and ∩ represents the overlap of the two contours. DC has been used in previous contouring studies to quantify the extent of overlap of two volumes (13, 17, 18); DC=1 represents perfect overlap, while DC=0 represents no overlap.…”
Section: Methodsmentioning
confidence: 99%
“…National and international cooperative groups and organizations have developed contouring atlases and seminars to help improve accuracy and standardize contouring. 1,2,12,13 Contouring atlases are useful but do not provide their users active feedback. Some contouring training programs provide contouring feedback to users, 14,15 and others do not.…”
Section: Introductionmentioning
confidence: 99%
“…3 In addition, contouring feedback may be given at the end of the training module without additional examination to assess for improvement after feedback. 13 It is a well-known concept in education that feedback is critical to more effective learning. 16,17 Training sessions that included feedback have shown good success.…”
Section: Introductionmentioning
confidence: 99%