2019
DOI: 10.1016/j.cllc.2019.02.019
|View full text |Cite
|
Sign up to set email alerts
|

A Prospective, Randomized Trial for the Comparison of 19-G and 22-G Endobronchial Ultrasound-Guided Transbronchial Aspiration Needles; Introducing a Novel End Point of Sample Weight Corrected for Blood Content

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
26
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(28 citation statements)
references
References 32 publications
2
26
0
Order By: Relevance
“…One systematic review from a clinical practice guideline produced on behalf of the World Association of Bronchology and Interventional Pulmonology Task Force, 27 2 randomized controlled trials (RCTs), 28,29 2 prospective cohort studies, 30,31 and 4 retrospective cohort studies [32][33][34][35] comprise the evidence base for statement 2. The systematic review 27 carried a low risk of bias, with the only limitation being unclear reporting of whether the study used dual study selection and data extraction.…”
Section: Guideline Statements Endobronchial Ultrasound-guided Transbronchial Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…One systematic review from a clinical practice guideline produced on behalf of the World Association of Bronchology and Interventional Pulmonology Task Force, 27 2 randomized controlled trials (RCTs), 28,29 2 prospective cohort studies, 30,31 and 4 retrospective cohort studies [32][33][34][35] comprise the evidence base for statement 2. The systematic review 27 carried a low risk of bias, with the only limitation being unclear reporting of whether the study used dual study selection and data extraction.…”
Section: Guideline Statements Endobronchial Ultrasound-guided Transbronchial Proceduresmentioning
confidence: 99%
“…The systematic review 27 carried a low risk of bias, with the only limitation being unclear reporting of whether the study used dual study selection and data extraction. Both RCTs, 28,29 1 prospective cohort study, 31 and all the retrospective cohort studies [32][33][34][35] were published after the search date of the systematic review. The aggregate risk of bias across these studies was very serious.…”
Section: Guideline Statements Endobronchial Ultrasound-guided Transbronchial Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…A more recent study using material from EBUS procedures 27 weighed the samples from 19G and 22G needles and found a mean weight per pass of 10.2 mg (0.0102 g) in the 22G group and 20.0 mg (0.02 g) in the 19G group. The nodes were sampled with three to five passes, each with 10‐15 needle thrusts.…”
Section: Discussionmentioning
confidence: 99%
“…As for the needle, the models available at present are mainly 25G, 22G, and 19G. In terms of sample quantity, 19G is better than 22G, with equivalent safety (10). The 22G and the 25G needles show no significant difference in diagnostic accuracy (11).…”
Section: Tbna and Intranodal Forceps Biopsy (Ifb)mentioning
confidence: 99%