2016 7th International Renewable Energy Congress (IREC) 2016
DOI: 10.1109/irec.2016.7478902
|View full text |Cite
|
Sign up to set email alerts
|

A proposal of energy management strategy on hybrid renewable system with hydrogen backup

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…In this case the different authors have eliminated the hysteresis bandwidth of the fuel cell operation (Table 4), maintaining the same SOCmin value and the rest of the simulation parameters similar to Case I. According to the results obtained from Case I and Case II, Tables 3 and 5 respectively, we can state that the use of the hysteresis band mode can reduce the startestop cycles of the fuel cell [45,46]. Besides, it requires higher operation time to reach the SOCfcmax value [45,46].…”
Section: Case II Sensitivity Analysis Examplementioning
confidence: 89%
See 2 more Smart Citations
“…In this case the different authors have eliminated the hysteresis bandwidth of the fuel cell operation (Table 4), maintaining the same SOCmin value and the rest of the simulation parameters similar to Case I. According to the results obtained from Case I and Case II, Tables 3 and 5 respectively, we can state that the use of the hysteresis band mode can reduce the startestop cycles of the fuel cell [45,46]. Besides, it requires higher operation time to reach the SOCfcmax value [45,46].…”
Section: Case II Sensitivity Analysis Examplementioning
confidence: 89%
“…The system configuration, cost and degradation parameters as well as the weather and the load profile (Fig. 10), are based on a real prototype implementation developed by different authors [45,46].…”
Section: Case Imentioning
confidence: 99%
See 1 more Smart Citation
“…The common practice is to set the dispatch model prior to size optimisation process or test different dispatch strategies to obtain best possible output of an optimal size of HRES [5][6][7][8]. For instance, PV-Diesel-Battery and Wind-PV-Battery-Diesel of HRES configurations presented in [9] and [10] respectively, battery discharging is given the priority to meet the demand level when primary energy supply falls short.…”
Section: Introductionmentioning
confidence: 99%
“…The production of clean energy, with zero CO 2 emissions, and the microgrid concept are closely related. A microgrid is responsible for managing energy flows from renewable production to and from storage systems and consumers [23,24].…”
Section: Introductionmentioning
confidence: 99%