A Preliminary Study on the Adaptive SNR Threshold Method for Depth of Penetration Measurements in Diagnostic Ultrasounds

Abstract: Maximum depth of penetration (DOP) is among the most relevant parameters in quality assurance programs for Ultrasound (US) scanners. Nowadays, a generally-accepted protocol for DOP estimation is still awaited and, in common practice, DOP is visually assessed despite the low accuracy. To overcome the eye-based assessment subjectivity, automatic image analysis methods have been proposed in literature. The present work focuses on a novel automatic method, namely the adaptive Signal to Noise Ratio (SNR) threshold … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
17
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
3

Relationship

3
5

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 24 publications
1
17
0
Order By: Relevance
“…As described in [19], [21], the AdSTM image analysis SNRbased method for DOP assessment (Fig. 1) was developed by 2 > REPLACE THIS LINE WITH YOUR MANUSCRIPT ID NUMBER (DOUBLE-CLICK HERE TO EDIT) < processing phantom and in-air clips (the latter obtained by decoupling the probe from the phantom surface).…”
Section: A Adaptive Snr Threshold Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…As described in [19], [21], the AdSTM image analysis SNRbased method for DOP assessment (Fig. 1) was developed by 2 > REPLACE THIS LINE WITH YOUR MANUSCRIPT ID NUMBER (DOUBLE-CLICK HERE TO EDIT) < processing phantom and in-air clips (the latter obtained by decoupling the probe from the phantom surface).…”
Section: A Adaptive Snr Threshold Methodsmentioning
confidence: 99%
“…The method, implemented through a custom-written MATLAB function, post-processes video clips taken from phantom and air observations by averaging N consecutive frames to produce two average images (Iph and Iair). Then, a rectangular Region Of Interest (ROI) of fixed width is automatically drawn from Iph and Iair to compute the signal and the noise contributions, respectively [19]. The SNR curve is then estimated as a function of depth z, and the threshold thSNR is computed as follows:…”
Section: A Adaptive Snr Threshold Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is important to underline that the experimental setup is the same, except for the three different methods. Following the procedure adopted in [7], Type A and Type B uncertainties will be combined [27], as follows (1): where Type A uncertainty, A, has been calculated directly from the standard deviation of the experimental data, while Type B uncertainty, B, has been obtained considering the uncertainties due to the power supply (evaluated from the datasheet), the optical system [7]- [9], the angle measurement, which uncertainty contribution has been assessed by means of a Monte Carlo simulation [28]- [29] in order to estimate the uncertainty related to the three implemented method.…”
Section: Uncertainty Analysismentioning
confidence: 99%
“…They can simulate the main acoustic characteristics of biological tissues and reproduce repeatable flows whose regimes are similar to those in blood vessels [4]- [7]. To date, the lack of a generally accepted standard for B-mode and Doppler [8]- [12], has led to a limitation on US phantoms use. It should be noticed that, even though such devices are widespread on the market, they are still not included in a shared standard that focuses in detail on periodic and objective checks of their metrological and functional characteristics.…”
Section: Introductionmentioning
confidence: 99%