2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA) 2022
DOI: 10.1109/memea54994.2022.9856474
|View full text |Cite
|
Sign up to set email alerts
|

A preliminary study on a novel approach to the assessment of the sample volume length and registration accuracy in PW Doppler quality control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(10 citation statements)
references
References 14 publications
0
10
0
Order By: Relevance
“…The velocity profile discrepancy index provides an estimation of faults in sample volume length and range gate registration accuracy [15,16], by quantifying the discrepancy between the actual velocities and the theoretical parabolic profile (under laminar flow assumption). As in [15,16], the sample volume (SV) was placed at six depths (from 35 to 37 mm and from 39 to 41 mm with steps of 1 mm) corresponding to six different positions with respect to the radius of the phantom tube. The objective measurement method estimates the mean maximum velocity vPW for each pre-set SV depth, and calculates VPDI [15,16] as in the following:…”
Section: B Test Parametersmentioning
confidence: 99%
See 3 more Smart Citations
“…The velocity profile discrepancy index provides an estimation of faults in sample volume length and range gate registration accuracy [15,16], by quantifying the discrepancy between the actual velocities and the theoretical parabolic profile (under laminar flow assumption). As in [15,16], the sample volume (SV) was placed at six depths (from 35 to 37 mm and from 39 to 41 mm with steps of 1 mm) corresponding to six different positions with respect to the radius of the phantom tube. The objective measurement method estimates the mean maximum velocity vPW for each pre-set SV depth, and calculates VPDI [15,16] as in the following:…”
Section: B Test Parametersmentioning
confidence: 99%
“…As in [15,16], the sample volume (SV) was placed at six depths (from 35 to 37 mm and from 39 to 41 mm with steps of 1 mm) corresponding to six different positions with respect to the radius of the phantom tube. The objective measurement method estimates the mean maximum velocity vPW for each pre-set SV depth, and calculates VPDI [15,16] as in the following:…”
Section: B Test Parametersmentioning
confidence: 99%
See 2 more Smart Citations
“…From the abovementioned considerations, the present study would give a contribution to the field of QCs for Doppler equipment testing, by proposing a comparative investigation of the Velocity Profile Discrepancy Index (VPDI), a quality parameter developed for the objective assessment of both SV length and range gate registration accuracy. The index, preliminarily defined and tested in [26], is estimated from the processing of PW Doppler spectrograms by means of a customwritten image analysis method developed in MATLAB environment. Three brand-new US diagnostic systems, each of them equipped with two ultrasound probes (convex and phased array) were tested in two working conditions.…”
Section: Introductionmentioning
confidence: 99%