A preliminary evaluation of a positron camera system using weighted decoding of individual crystals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

1989
1989
2016
2016

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…With the subsequent transition of PET imaging to primarily 18 F-FDG oncology studies, the benefit of TOF PET with these early scintillators could not help overcome the reduced sensitivity and worse spatial resolution. Hence, the 1990s saw PET system design dominated by Non-TOF scanners primarily using BGO crystals with septa for 2D data acquisition [12,13], or alternately using large NaI(Tl) crystals without septa for fully-3D data acquisition [14,15]. …”
Section: Brief History Of Tof Petmentioning
confidence: 99%
“…With the subsequent transition of PET imaging to primarily 18 F-FDG oncology studies, the benefit of TOF PET with these early scintillators could not help overcome the reduced sensitivity and worse spatial resolution. Hence, the 1990s saw PET system design dominated by Non-TOF scanners primarily using BGO crystals with septa for 2D data acquisition [12,13], or alternately using large NaI(Tl) crystals without septa for fully-3D data acquisition [14,15]. …”
Section: Brief History Of Tof Petmentioning
confidence: 99%
“…Attenuation correction is based on transmission scans for which a rotating line source is used. The number of registered random and scattered coincidences is drastically reduced by the use of the line source instead of a ring source, which is applied in many other PET scanners (Thompson et al 1986;Holte et al 1988). Due to the line source it is possible to perform transmission scans even after the injection of the radiopharmaceutical without major errors or the need for specific correction procedures (Carroll et al 1983;Carson et al 1988).…”
Section: Livermentioning
confidence: 99%
“…A technique suitable to identify signals from small crystals in PET is a modified form of the Anger technique (Anger, 1963;Burnham et al, 1985), called the blockdetector method (Murayama et al, 1982;Casey & Nutt, 1986;Eriksson et al, 1986;Dahlbom & Hoffman, 1988;Holte et al, 1988). Figure 6(a) shows an example of a detector block with four scintillators directly mounted on two PMT.…”
Section: Block-detector Conceptmentioning
confidence: 99%
“…A number of instruments, positron cameras or PET scanners, with different design parameters have been developed for this purpose. Some are designed to study the distribution of positron emitters in the brain (Cho et al, 1976;Bohm et al, 1978; Hoffman et al, 1982; Bergstrom, 1982;Litton et al, 1984; Kanno et al, 1985), while others are dedicated to other parts of the body (Phelps et al, 1975;Williams et al, 1979;Hoffman et al, 1983;Budinger et al, 1984;Holte et al, 1988). The data obtained are used to reconstruct images describing these distributions.…”
Section: Introductionmentioning
confidence: 99%