2012
DOI: 10.1109/tia.2012.2210172
|View full text |Cite
|
Sign up to set email alerts
|

A Practical Solution to Mitigate Vibrations in Industrial PM Motors Having Concentric Windings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
16
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(18 citation statements)
references
References 17 publications
0
16
0
1
Order By: Relevance
“…2b. Similarly, based on (9), it can also be solved that P r (4th, 4400 Hz) comes from the interaction of n 1 th and n 2 th permanent magnet field (where n 1 ± n 2 = 22) and the seventh permeance harmonic.…”
Section: Calculation and Analysis Of Electromagnetic Vibration And Nomentioning
confidence: 99%
See 1 more Smart Citation
“…2b. Similarly, based on (9), it can also be solved that P r (4th, 4400 Hz) comes from the interaction of n 1 th and n 2 th permanent magnet field (where n 1 ± n 2 = 22) and the seventh permeance harmonic.…”
Section: Calculation and Analysis Of Electromagnetic Vibration And Nomentioning
confidence: 99%
“…In [4,5], 1D fast Fourier transform (FFT) is adopted to perform harmonic analysis for the time history of radial force at a certain spatial point or for the spatial distribution of radial force at a certain temporal point. The 1D analysis of radial force is widely used and can also be found in [6][7][8][9]. However, the frequency components of radial force with specifically spatial order cannot be obtained by using 1D analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Although they conclude that skewing the stator slots and skewing the rotor magnets has the same effect and skewing one cogging torque period can eliminate the cogging torque, this method does not provide practical field distribution for a skewed machine. Slot skewing that can improve the back electromotive force (back-EMF) and suppress mutual torque ripple with insignificant motor structure change has been widely used in the electrical machine production [13][14] . For slot skewing, air-gap flux distribution varies along the entire length of the machine in the axial direction, which introduces a number of problems in the field calculation and performance analysis of machines with skewed slots [15] .…”
Section: Introductionmentioning
confidence: 99%
“…Since mechanical vibration is harmful to the robustness of an integration system and generates audible noise, which is a critical factor in human sensitivity, vibration reduction has become an important issue in motor design [1]- [3]. Many studies have noted that the main sources of motor vibration are fluctuation of the magnetic force and mechanical deformation of the motor structure [4]- [5].…”
Section: Introductionmentioning
confidence: 99%