“…Even the grid is strong enough that a large virtual inertia support is not needed for VVSG operating in the grid-connected mode, but the first-order low-pass filter of output active power still performs the same time-delay effect. In order to filter out power pulsations induced by grid harmonics or nonlinear loads, the filter cutoff frequency is generally set to two to five times the fundamental frequency in tenths, hence the response speed of the output active power is reduced [25,26]. Setting J ω = 1, and increasing T f gradually, the zero and poles trend of G r (s) is shown in Figure 4.…”
Section: Primary Frequency Regulationmentioning
confidence: 99%
“…Even the grid is strong enough that a large virtual inertia support is not needed for VVSG operating in the grid-connected mode, but the first-order low-pass filter of output active power still performs the same time-delay effect. In order to filter out power pulsations induced by grid harmonics or nonlinear loads, the filter cutoff frequency is generally set to two to five times the fundamental frequency in tenths, hence the response speed of the output active power is reduced [25,26]. Setting J ω = 1, and increasing T f gradually, the zero and poles trend of G r (s) is shown in Figure 4.…”
Section: Primary Frequency Regulationmentioning
confidence: 99%
“…However, the aforementioned controllers [2026] are not capable to provide secondary frequency regulation, which is a necessary feature in the weak grid scenario. Therefore, a secondary frequency controller is presented in [28, 29] to deal with a VSG. These secondary frequency controllers [28, 29] are implemented thorough a PI regulator, which makes system sluggish and required rigorous tuning.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, a secondary frequency controller is presented in [28, 29] to deal with a VSG. These secondary frequency controllers [28, 29] are implemented thorough a PI regulator, which makes system sluggish and required rigorous tuning. However, the experimental performance is not analysed for [28, 29] to validate the practical implementation of power converter applications.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations