1997
DOI: 10.1006/jmre.1996.1094
|View full text |Cite
|
Sign up to set email alerts
|

A Practical Method for Automated Shimming with Normal Spectrometer Hardware

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

1997
1997
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(16 citation statements)
references
References 5 publications
0
16
0
Order By: Relevance
“…Automated z-gradient shimming was carried out using deuterium spin echoes. 23 DOSY spectra were measured using the BPPSTE sequence 1,5 and the newer one-shot sequence of Fig. 1(b).…”
Section: Methodsmentioning
confidence: 99%
“…Automated z-gradient shimming was carried out using deuterium spin echoes. 23 DOSY spectra were measured using the BPPSTE sequence 1,5 and the newer one-shot sequence of Fig. 1(b).…”
Section: Methodsmentioning
confidence: 99%
“…(Although some older instru-system (Tecmag, Houston, TX) replacing the original Nicolet 1280 computer, but otherwise unmodified. The 1 H decouments do have a ''homospoil'' control which allows pulses on the Z shim coil, these permit mapping the Z axis only (34).) pler coil of a 20-mm broadband probe (Nalorac, Martinez, CA) was used for all measurements.…”
Section: Methodsmentioning
confidence: 99%
“…2. The only hardware modifications to the two instruments were the addition of automatic radiofrequency switching for convenience when using deuterium z phase profile shimming, and a change to the value of one capacitor in the homospoil duration limit circuitry of the shim current controller (6). Software for the analysis of the profile data was implemented in C within the Vnmr software package, using the approach described above with the singular value decomposition algorithm of Ref.…”
Section: Figmentioning
confidence: 99%
“…For most samples it is also sufficient to shim only along the z axis, since this is the direction along which most of the sampleto-sample variation in field homogeneity is concentrated, and the effects of field variation orthogonal to z can be efficiently minimized by sample spinning. z axis shimming using the deuterium lock signal for single axis spin echo phase mapping has been shown to be highly efficient both in systems equipped with a z axis pulsed field gradient (5,6) and in systems with only the slow ''homospoil'' facility to pulse the current through the z 1 shim coil (6).…”
mentioning
confidence: 99%