2021
DOI: 10.1016/j.foodchem.2021.129318
|View full text |Cite
|
Sign up to set email alerts
|

A practical and fast isolation of 12 cyclolinopeptides (linusorbs) from flaxseed oil via preparative HPLC with phenyl-hexyl column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 23 publications
0
7
0
Order By: Relevance
“…In total, 15 cyclic peptides could be identified with elution orders F, G, K, C, T, I, D, P, E, N, B, O, A, L, and M. Aladedunye et al ( 24 ) identified 14 CLPs in flaxseed oil, F, G, C, E, I, D, H, N, B, L, A, J, M, and K, using a Kinetex Column and HPLC Exactive Orbitrap MS. Lao and his group identified 15 CLPs, F, G, C, E, T, H, D, I, P, B, A, L, N, O, and M, using a Kinetex TM phenyl-hexyl column and MALDI quadrupole/TOF prototype mass spectrometry ( 17 ). In 2021, in the CLP isolation experiment, 15 CLPs were identified using a Kinetex TM phenyl hexyl column with a TripleTOF 5600 mass analyzer ( 32 ). Other groups identified up to 7 CLPs using Hybrid Quadrupole-TOF MS/MS with monolithic and microparticulate columns ( 29 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In total, 15 cyclic peptides could be identified with elution orders F, G, K, C, T, I, D, P, E, N, B, O, A, L, and M. Aladedunye et al ( 24 ) identified 14 CLPs in flaxseed oil, F, G, C, E, I, D, H, N, B, L, A, J, M, and K, using a Kinetex Column and HPLC Exactive Orbitrap MS. Lao and his group identified 15 CLPs, F, G, C, E, T, H, D, I, P, B, A, L, N, O, and M, using a Kinetex TM phenyl-hexyl column and MALDI quadrupole/TOF prototype mass spectrometry ( 17 ). In 2021, in the CLP isolation experiment, 15 CLPs were identified using a Kinetex TM phenyl hexyl column with a TripleTOF 5600 mass analyzer ( 32 ). Other groups identified up to 7 CLPs using Hybrid Quadrupole-TOF MS/MS with monolithic and microparticulate columns ( 29 ).…”
Section: Resultsmentioning
confidence: 99%
“…Additionally, it is important to mention that some other groups managed to separate 11 and 12 CLPs using RP-HPLC. However, applying time-consuming and expensive approaches for extraction and elution, where gradients of acetonitrile-water were used, with flows of 2 and 16 ml/min ( 30 , 32 ). A potential limitation of using methanol as the eluent would be an occasional drift in the baseline, which was also reported in other publications ( 24 ).…”
Section: Resultsmentioning
confidence: 99%
“…The extract was combined and removed the solvent at 50°C by a rotary evaporator. Column chromatography was used to purify the extract, and then, the purified products were separated into reduced LOs and oxidized LOs following the previous method with modifications by preparative‐HPLC‐PDA (Reveleris® Prep Purification System; Grace Inc., Columbia, MD) and equipped with VisionHT C18 HT column (250 × 22 mm, 10 μm; Grace Inc., Columbia, MD) (19). In detail, acetonitrile and ultrapure water were used as mobile phase for gradient elution, initial acetonitrile ratio of 40%, and increased to 80% within 30 min, then increased to 100% within 0.5 min and maintained 3 min, with the flow rate of 16 mL min −1 , loaded sample of 5 mL with concentration of 20 mg mL −1 .…”
Section: Methodsmentioning
confidence: 99%
“…[17][18][19][20] Among them, HPLC has the advantages of fast separation, high sensitivity, strong reproducibility and wide application elds, playing an increasingly important role in the detection and separation of racemic drugs. 21,22 However, the lack of a universal chiral selector translates into the need to design and fabricate novel chiral stationary phases (CSPs) in HPLC.…”
Section: Introductionmentioning
confidence: 99%