A platform for specific and sensitive detection of target bacteria by selective magnetic enrichment and a broad-spectrum fluorescent probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…The probe can be easily prepared by dissolving europium acetate in an aqueous solution. In contrast, sensing probes produced by other existing methods required varying durations, ranging from a few tens of minutes to several tens of hours. As mentioned earlier, the LOD of our method for S. aureus was approximately 10 4 CFU mL –1 , determined through the calibration curve presented in Supporting Information Figure S10. When our LOD is compared with those obtained from other existing methods, it becomes apparent that our LOD is higher than those achieved by the existing methods.…”
Section: Resultsmentioning
confidence: 86%
“…The probe can be easily prepared by dissolving europium acetate in an aqueous solution. In contrast, sensing probes produced by other existing methods required varying durations, ranging from a few tens of minutes to several tens of hours. As mentioned earlier, the LOD of our method for S. aureus was approximately 10 4 CFU mL –1 , determined through the calibration curve presented in Supporting Information Figure S10. When our LOD is compared with those obtained from other existing methods, it becomes apparent that our LOD is higher than those achieved by the existing methods.…”
Section: Resultsmentioning
confidence: 86%
“…The LODs of SA and MRSA are comparable with those reported in the literature (Table S1). The result indicates that the as-proposed strategy can be used for quantitative detection of SA and MRSA with high sensitivity. In addition, the intensities of corresponding green fluorescence images are increased by increasing the concentrations of SA and MRSA, while the intensities of corresponding red fluorescence images are only increased by increasing the concentration of MRSA.…”
Section: Resultsmentioning
confidence: 90%
“…Fluorescent nanoprobes coupled with magnetic nanoparticles have demonstrated great application prospects in separation and detection, enabling rapid recognition and sensitive detection of trace proteins in complex real samples. [133][134][135] Liposome-like C dots and C dot-nanovesicles with brightness and insignificant blinking are efficient drug/dye carriers, showing their potential for sensing, cell imaging, and cell tracking. [132] It is thus highly expected that multifunctional C dots and MNCs can be prepared by carefully selecting ligands/precursors.…”
Section: Discussionmentioning
confidence: 99%