2022
DOI: 10.1134/s1061934822040049
|View full text |Cite
|
Sign up to set email alerts
|

A Piezoelectric Immunosensor Based on Magnetic Carbon Nanocomposites for the Determination of Ciprofloxacin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 24 publications
0
3
0
1
Order By: Relevance
“…Introducing piezoelectricity into this concept, the composite was then used as the recognition layer for a novel piezoelectric immunosensor. The result of this creative approach was the sensitive and selective determination of ciprofloxacin in various food products with a LOD of 2 ng/mL for MCNC1 and 8 ng/mL for MCNC2 [100]. Furthermore, Bizina and colleagues reported that the linear range of the developed sensor was reported to be 5-400 ng/mL [100].…”
Section: Immunosensors Used For Quinolone Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…Introducing piezoelectricity into this concept, the composite was then used as the recognition layer for a novel piezoelectric immunosensor. The result of this creative approach was the sensitive and selective determination of ciprofloxacin in various food products with a LOD of 2 ng/mL for MCNC1 and 8 ng/mL for MCNC2 [100]. Furthermore, Bizina and colleagues reported that the linear range of the developed sensor was reported to be 5-400 ng/mL [100].…”
Section: Immunosensors Used For Quinolone Detectionmentioning
confidence: 99%
“…Bizina and colleagues managed to merge carbon nanotubes with magnetic nanoparticles (Fe 3 O 4 NPs) to form two kinds of magnetic carbon composites (MCNC1/2) [100]. Introducing piezoelectricity into this concept, the composite was then used as the recognition layer for a novel piezoelectric immunosensor.…”
Section: Immunosensors Used For Quinolone Detectionmentioning
confidence: 99%
“…The immunosensor achieved the LOD of 9 ng mL −1 and 8 ng mL −1 for levofloxacin (LEV) and CIP, respectively. Similarly, Bizina et al ( 2022 ) developed a piezoelectric immunosensor with a recognition layer based on magnetic carbon nanocomposites for CIP detection in milk and meat sample. The receptor coating of the sensor was formed by the action of magnetic field on magnetic particles located on the surface of CNTs modified with a CIP conjugate.…”
Section: Electrochemical Biosensors For Fqsmentioning
confidence: 99%
“…Для определения содержания лекарственных соединений в биологических объектах требуются высокочувствительные, селективные и несложные методы. Такими преимуществами обладают пьезоэлектрические [5,6] и электрохимические иммуносенсоры [7,8] [9 -13]. Для более эффективного закрепления на поверхности трансдьюсеров модификаторы наносят совместно с гиперразветвленными структурами (полиэфирополиолы) или дендримерами [14].…”
unclassified