2020
DOI: 10.1007/s10147-020-01665-2
|View full text |Cite
|
Sign up to set email alerts
|

A phase II study of adaptive two-step intensity-modulated radiation therapy (IMRT) with chemotherapy for loco-regionally advanced nasopharyngeal cancer (JCOG1015)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 38 publications
0
11
0
Order By: Relevance
“…All 101 patients were treated using a two‐step intensity‐modulated RT (IMRT) technique. At our institution, a two‐step method is used for head and neck cancers instead of the simultaneous integrated boost method 20 . The procedure of two‐step IMRT has been previously described in detail 8 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…All 101 patients were treated using a two‐step intensity‐modulated RT (IMRT) technique. At our institution, a two‐step method is used for head and neck cancers instead of the simultaneous integrated boost method 20 . The procedure of two‐step IMRT has been previously described in detail 8 .…”
Section: Methodsmentioning
confidence: 99%
“…At our institution, a two‐step method is used for head and neck cancers instead of the simultaneous integrated boost method. 20 The procedure of two‐step IMRT has been previously described in detail. 8 In short, whole neck RT of 44.0–50.0 Gy/22–25 fractions was delivered, followed by boost doses to the high‐risk clinical target volume (CTV) up to a total dose of 70.0 Gy/35 fractions.…”
Section: Methodsmentioning
confidence: 99%
“…IMRT/VMAT will be utilized in various JCOG clinical trials not only in the JCOG-RTSG but also in other JCOG study groups using radiotherapy. The multicenter clinical trials that are representative of the JCOG-RTSG are JCOG1015 [ 9 ], JCOG1208 for head and neck, and JCOG1402 (a joint study with the JCOG Gynecologic Cancer Study Group) for the uterus and cervix. In JCOG1008, JCOG1212, JCOG1303, JCOG1703 and JCOG1910, which are representative of the JCOG Head and Neck Cancer Study Group and Brain Tumor Study Group, IMRT/VMAT is used.…”
Section: Dosimetry Audit System For Imrt/vmat Clinical Trials: Jcog10mentioning
confidence: 99%
“…This was a prospective clinical study (JCOG1015) based on an original study by Nishimura et al in Japan with IMXT. 9,21 That protocol was based on practical standard IMXT in Japan for nasopharyngeal carcinoma. Our IMPT study was designed to be compatible with that protocol.…”
Section: B | Target Volume Oars and Dose Prescriptionmentioning
confidence: 99%